16ELECTRICAL DATATable 17 – 24AHA4/124ANS Electrical DataUnit Size --voltage series V/PH OPER VOLTS* COMPR FAN MCAMAX FUSE**or CKT BRKAMPSMAX MIN LRA RLA FLA18--30208/230/1 253 19756.3 9.0 0.50 11.8 2024--30 62.9 10.9 0.50 14.1 2530--30 73.0 14.1 0.70 18.3 3036--30 77.0 14.1 1.20 18.8 3036--50 208/230/1 253 197 71.0 9.0 1.20 12.5 2036--60 460/3 506 414 38.0 5.6 0.60 7.6 15Table 18 – 25HHA4/224ANS Electrical DataUnit SizeVoltage Series V/PH OPER VOLTS COMP FAN MCAMAX FUSE**or CKT BRKAMPSMAX MIN LRA RLA FLA24--30208/230/1 253 19758.3 12.8 0.50 16.5 2530--30 64.0 12.8 1.20 17.2 3036--30 77.0 14.2 1.20 19.0 3036--50 208/230/3 253 197 71.0 9.3 1.20 12.8 2036--60 460/3 506 414 38.0 5.6 0.60 7.6 15Table 19 – 40MKCB**C Electrical DataIndoor Unit SizeBTU/Hr V--Ph--HzVoltage Range Fan PowerMin (V) Max (V) FLA (A) Min Ckt Amp (A) Max Fuse CB Amp(A)18K 208–230 -- 1 -- 60 187 253 0.332 1 1524K – 34K 208–230 -- 1 -- 60 187 253 0.8 1 15Table 20 – 40MKQB**C Electrical DataIndoor Unit SizeBTU/Hr V--Ph--HzVoltage Range Fan PowerMin (V) Max (V) FLA (A) Min Ckt Amp (A) Max Fuse CB Amp(A)24K – 34K 208–230 -- 1 -- 60 187 253 0.8 1 15LEGENDFLA --- Full Load AmpsHACR--- Heating, Air Conditioning, RefrigerationLRA--- Locked Rotor AmpsNEC--- National Electrical CodeRLA--- Rated Load Amps (compressor)*Permissible limits of the voltage range at which the unit will operate satisfactorily**Time--- Delay fuse.Complies with 2007 requirements of ASHRAE Standards 90.1