EN7-EN 8-EN– 4 –• Wear protective gloves and safety work clothing duringinstallation, servicing and removal.• Do not touch the aluminium n of the unit. You may injureyourself if you do so. If the n must be touched for somereason, rst put on protective gloves and safety work clothing,and then proceed.• Do not climb onto or place objects on top of the outdoor unit.You may fall or the objects may fall off of the outdoor unit andresult in injury.• When work is performed at heights, use a ladder whichcomplies with the ISO 14122 standard, and follow theprocedure in the ladder’s instructions. Also wear a helmet foruse in industry as protective gear to undertake the work.• Before cleaning the lter or other parts of the outdoor unit, setthe circuit breaker to OFF without fail, and place a “Work inprogress” sign near the circuit breaker before proceeding withthe work.• Before working at heights, put a sign in place so that no-one willapproach the work location, before proceeding with the work.Parts and other objects may fall from above, possibly injuringa person below. While carrying out the work, wear a helmet forprotection from falling objects.• Do not use the refrigerant other than R32.For the refrigerant type, check the outdoor unit to be combined.• The refrigerant used by this air conditioner, follow to the outdoorunit.• The air conditioner must be transported in stable condition. Ifany part of the product is broken, contact the dealer.• When the air conditioner must be transported by hand, carry itby two or more people.• Do not move or repair any unit by yourself. There is highvoltage inside the unit. You may get electric shock whenremoving the cover and main unit.• This appliance is intended to be used by expert or trained usersin shops, in light industry, or for commercial use by lay persons.Selection of installation location• When the air conditioner is installed in a small room, provideappropriate measures to ensure that the concentration ofrefrigerant leakage occur in the room does not exceed thecritical level.• Do not install in a location where ammable gas leaks arepossible. If the gas leak and accumulate around the unit, it mayignite and cause a re.• To transport the air conditioner, wear shoes with additionalprotective toe caps.• To transport the air conditioner, do not take hold of the bandsaround the packing carton. You may injure yourself if the bandsshould break.• Install the indoor unit at least 2.5 m above the oor level sinceotherwise the users may injure themselves or receive electricshocks if they poke their ngers or other objects into the indoorunit while the air conditioner is running.• Do not place any combustion appliance in a place where it isdirectly exposed to the wind of air conditioner, otherwise it maycause imperfect combustion.• Appliance and pipe-work shall be installed, operated and storedin a room with a oor area larger than A min m2.How to get Amin m2 : Amin = (M / (2.5 × 0.22759 × h0 ))2M is the refrigerant charge amount in appliance in kg;h 0 is the installation height of the appliance in m:0.6 m for oor standing / 1.8 m for wall mounted / 1.0 m forwindow mounted / 2.2 m for ceiling mounted. (For these units(R32 refrigerant models only. For detail, refer to InstallationManualof the outdoor unit.)Installation• When the indoor unit is to be suspended, the designated hangingbolts (M10 or W3/8) and nuts (M10 or W3/8) must be used.• Install the air conditioner securely in a location where the basecan sustain the weight adequately. If the strength is not enough,the unit may fall down resulting in injury.recommend installation height 2.5 m.)