38COOLING PERFORMANCEALL 7000 NOMINAL BTUH MODELSEvaporator entering air temp. — 80 F Evap. air — 260 CFMLEGENDNOTES:1. Total current (I) based on 230-volt system.2. Evaporator entering dry bulb air temperature is 80° F.ALL 9000 NOMINAL BTUH MODELSEvaporator entering air temp. — 80 F Evap. air — 260 CFMLEGENDNOTES:1. Total current (I) based on 230-volt system.2. Evaporator entering dry bulb air temperature is 80° F.52CQ 12,000 NOMINAL BTUH MODELSEvaporator entering air temp. — 80 F Evap. air — 350 CFMLEGENDNOTES:1. Total current (I) based on 230-volt system.2. Evaporator entering dry bulb air temperature is 80° F.52PC,PE,CE 12,000 NOMINAL BTUH MODELSEvaporator entering air temp. — 80 F Evap. air — 350 CFMLEGENDNOTES:1. Total current (I) based on 230-volt system.2. Evaporator entering dry bulb air temperature is 80° FTEMP (F) AIR ENT.COND (40% RH)EVAP AIR — EWB (F)57.00 62.00 67.00 72.0080MBtuh 7.05 7.23 8.04 8.85kW 0.54 0.54 0.55 0.55I 2.35 2.36 2.37 2.3985MBtuh 6.93 7.08 7.90 8.71kW 0.56 0.57 0.57 0.57I 2.45 2.46 2.48 2.4990MBtuh 6.85 6.95 7.72 8.54kW 0.59 0.59 0.59 0.60I 2.56 2.56 2.58 2.5995MBtuh 6.76 6.81 7.54 8.35kW 0.61 0.61 0.62 0.62I 2.67 2.67 2.68 2.89100MBtuh 6.70 6.70 7.36 8.17kW 0.64 0.64 0.64 0.64I 2.79 2.79 2.79 2.80105MBtuh 6.57 6.59 7.17 7.98kW 0.67 0.67 0.67 0.67I 2.91 2.91 2.91 2.92110 MBtuh 6.42 6.41 6.97 7.79kW 0.70 0.70 0.70 0.70I 3.03 3.04 3.03 3.03115 MBtuh 6.28 6.27 6.76 7.59kW 0.73 0.73 0.72 0.73I 3.17 3.17 3.17 3.16EWB — Entering Wet BulbI — Compressor Current AmpskW — Total PowerMBtuh — Total Cooling CapacityRH — Relative HumidityTEMP (F) AIR ENT.COND (40% RH)EVAP AIR — EWB (F)57.00 62.00 67.00 72.0080MBtuh 8.58 8.91 9.71 10.46kW 0.71 0.72 0.71 0.71I 3.14 3.14 3.13 3.1285MBtuh 8.44 8.72 9.56 10.48kW 0.75 0.75 0.74 0.74I 3.28 3.28 3.27 3.2790MBtuh 8.29 8.52 9.47 10.39kW 0.78 0.78 0.78 0.78I 3.44 3.44 3.42 3.4195MBtuh 8.12 8.30 9.29 10.26kW 0.82 0.82 0.81 0.81I 3.59 3.60 3.58 3.56100MBtuh 7.94 8.07 9.06 10.07kW 0.85 0.85 0.85 0.85I 3.74 3.74 3.74 3.72105MBtuh 7.75 7.84 8.83 9.80kW 0.89 0.89 0.89 0.88I 3.89 3.90 3.92 3.89110 MBtuh 7.57 7.60 8.59 9.67kW 0.92 0.93 0.93 0.92I 4.06 4.07 4.10 4.06115 MBtuh 7.38 7.38 8.32 9.41kW 0.96 0.97 0.97 0.97I 4.24 4.24 4.27 4.24EWB — Entering Wet BulbI — Compressor Current AmpskW — Total PowerMBtuh — Total Cooling CapacityRH — Relative HumidityTEMP (F) AIR ENT.COND (40% RH)EVAP AIR — EWB (F)57.00 62.00 67.00 72.0080 MBtuh 12.44 12.74 13.61 13.84kW 1.06 1.06 1.05 1.02I 4.65 4.65 4.59 4.4885 MBtuh 12.29 12.51 13.52 13.90kW 1.10 1.10 1.09 1.07I 4.85 4.84 4.80 4.6990 MBtuh 12.10 12.29 13.20 13.84kW 1.15 1.15 1.13 1.11I 5.05 5.05 4.98 4.9195MBtuh 11.89 12.01 12.97 13.70kW 1.20 1.20 1.18 1.17I 5.26 5.26 5.18 5.12100MBtuh 11.66 11.73 12.72 13.34kW 1.25 1.25 1.23 1.21I 5.48 5.48 5.40 5.31105MBtuh 11.43 11.48 12.40 13.12kW 1.30 1.30 1.28 1.26I 5.70 5.70 5.62 5.52110MBtuh 11.19 11.23 12.20 12.98kW 1.35 1.35 1.33 1.31I 5.94 5.94 5.86 5.76115MBtuh 10.94 10.98 11.91 12.73kW 1.41 1.41 1.39 1.37I 6.18 6.18 6.10 6.00EWB — Entering Wet BulbI — Compressor Current AmpskW — Total PowerMBtuh — Total Cooling CapacityRH — Relative HumidityTEMP (F) AIR ENT.COND (40% RH)EVAP AIR — EWB (F)57.00 62.00 67.00 72.0080 MBtuh 12.17 12.50 12.83 13.23kW 1.07 1.07 1.05 1.03I 4.73 4.74 4.65 4.5785 MBtuh 11.95 12.35 12.72 13.19kW 1.11 1.11 1.10 1.08I 4.93 4.95 4.86 4.7990 MBtuh 11.74 12.10 12.62 13.06kW 1.16 1.16 1.15 1.13I 5.14 5.16 5.08 5.0095MBtuh 11.54 11.90 12.50 12.95kW 1.21 1.21 1.20 1.17I 5.36 5.38 5.31 5.21100MBtuh 11.37 11.68 12.35 12.80kW 1.26 1.26 1.25 1.23I 5.58 5.60 5.54 5.45105MBtuh 11.19 11.47 12.17 12.63kW 1.31 1.31 1.30 1.28I 5.81 5.83 5.78 5.68110MBtuh 11.04 11.28 11.93 12.44kW 1.37 1.37 1.35 1.33I 6.06 6.07 6.01 5.92115MBtuh 10.86 11.02 11.59 12.19kW 1.42 1.42 1.41 1.39I 6.31 6.31 6.25 6.17EWB — Entering Wet BulbI — Compressor Current AmpskW — Total PowerMBtuh — Total Cooling CapacityRH — Relative HumidityEXPANDED RATINGS DATA (52P AND 52C)