4. If you touch ungrounded objects (recharge your body withstatic electricity), firmly touch furnace again before touchingcontrol or wires.5. Use this procedure for installed and uninstalled (ungrounded)furnaces.6. Before removing a new control from its container, dischargeyour body’s electrostatic charge to ground to protect thecontrol from damage. If the control is to be installed in afurnace, follow items 1 through 5 before bringing the controlor yourself into contact with the furnace. Put all used ANDnew controls into containers before touching ungroundedobjects.7. An ESD service kit (available from commercial sources) mayalso be used to prevent ESD damage.INTRODUCTIONThe 58MSA Multipoise Condensing Gas-Fired Furnaces areA.G.A./C.G.A. certified for natural and propane gases and forinstallation in alcoves, attics, basements, closets, utility rooms,crawlspaces, and garages. The furnace is factory-shipped for usewith natural gas. An A.G.A/C.G.A certified gas conversion kit isrequired to convert furnace for use with propane gas. Thesefurnaces are suitable for installation in a residence built on site ora manufactured residence completed at final site. The design ofthis furnace line is NOT A.G.A./C.G.A. certified for installation inrecreation vehicles, in manufactured (mobile) homes, or outdoors.These furnaces SHALL NOT be installed directly on carpeting,tile, or any other combustible material other than wood flooring. Indownflow installations, factory accessory floor base MUST beused when installed on combustible materials and wood flooring.These furnaces are shipped with the drain and pressure tubesconnected for UPFLOW applications. Minor modifications arerequired when used in DOWNFLOW, HORIZONTAL RIGHT, orHORIZONTAL LEFT (supply-air discharge direction) applica-tions as shown in Fig. 1. See details in Applications section.These furnaces are shipped with the following materials to assist inproper furnace installation. These materials are shipped in the mainblower compartment.Installer Packet includes:Installation, Start-Up, and Operating InstructionsService and Maintenance InstructionsUser’s Information ManualWarranty CertificateLoose Parts Bag includes: QuantityPressure tube extension 1Collector box or condensate trap extension tube 1Inducer housing drain tube 11/2-in. CPVC street elbow 2Drain tube coupling 1Drain tube coupling grommet 1Vent and combustion-air pipe support 2Combustion-air pipe perforated disk assembly 1Vent Pipe Extension 1** ONLY supplied with some furnaces.This furnace must be installed with a direct-vent (combustion airand flue) system and a factory accessory termination kit. In adirect-vent system, all air for combustion is taken directly from theoutside atmosphere and all flue products are discharged to theoutside atmosphere. See furnace and factory accessory terminationkit instructions for proper installation.Before installing the furnace in the United States, refer to thecurrent edition of the NFGC and the NFPA 90B.For copies of the NFGC and NFPA 90B contact the National FireProtection Association Inc., Batterymarch Park, Quincy, MA02269; or American Gas Association, 1515 Wilson Boulevard,Arlington, VA 22209.Before installing the furnace in Canada, refer to the NSCNGPIC.Contact Standard Sales, CSA International, 178 Rexdale Boule-vard, Etobicoke, (Toronto) Ontario, Canada M9W 1R3.Installation must comply with regulations of serving gas supplierand local building, heating, plumbing or other codes in effect in thearea in which installation is made. In the absence of local codes,installation must comply with the NFGC in the United States andthe NSCNGPIC in Canada.These instructions cover minimum requirements for a safe instal-lation and conform to existing national standards and safety codes.In some instances, these instructions exceed certain local codesand ordinances, especially those that may not have kept pace withchanging residential construction practices. We require theseinstructions as a minimum for a safe installation.Application of this furnace should be indoors with specialattention given to vent sizing and material, gas input rate, airtemperature rise, unit leveling, and unit sizing. Improperinstallation or misapplication of furnace can require excessiveservicing or cause premature component failure.Improper installation, adjustment, alteration, service, mainte-nance, or use can cause carbon monoxide poisoning, explo-sion, fire, electrical shock, or other conditions which maycause personal injury or property damage. Consult a qualifiedinstaller, service agency, local gas supplier, or your distribu-tor or branch for information or assistance. The qualifiedinstaller or agency must use only factory-authorized andlisted kits or accessories when modifying this product. Failureto follow this warning could result in electrical shock, fire,personal injury, or death.For accessory installation details, refer to applicable installationliterature.APPLICATIONSStep 1—GeneralSome assembly and modifications are required for furnacesinstalled in any of the 4 applications shown in Fig. 1. All drain andpressure tubes are connected as shown in Fig. 5. See appropriateapplication instructions for these procedures.Step 2—Upflow ApplicationsAn upflow furnace application is where furnace blower is locatedbelow combustion and controls section of furnace, and conditionedair is discharged upwards.CONDENSATE TRAP LOCATION (FACTORY-SHIPPEDORIENTATION)The condensate trap is factory installed in the blower shelf andfactory connected for UPFLOW applications. A factory-suppliedtube is used to extend the condensate trap drain connection to thedesired furnace side for field drain attachment. See CondensateTrap Tubing (Factory-Shipped Orientation) section for drain tubeextension details.4