CODES AND STANDARDSFollow all national and local codes and standards in addition tothese instructions. The installation must comply with regulationsof the serving gas supplier, local building, heating, plumbing, andother codes. In absence of local codes, the installation mustcomply with the national codes listed below and all authoritieshaving jurisdiction.In the United States and Canada, follow all codes and standards forthe following:Step 1—Safety• US: National Fuel Gas Code (NFGC) NFPA 54-2002/ANSIZ223.1-2002 and the Installation Standards, Warm Air Heatingand Air Conditioning Systems ANSI/NFPA 90B• CANADA: National Standard of Canada, Natural Gas andPropane Installation Code (NSCNGPIC) CSA B149.1-00.Step 2—General Installation• US: NFGC and the NFPA 90B. For copies, contact the NationalFire Protection Association Inc., Batterymarch Park, Quincy,MA 02269; or for only the NFGC contact the American GasAssociation, 400 N. Capitol, N.W., Washington DC 20001• CANADA: NSCNGPIC. For a copy, contact Standard Sales,CSA International, 178 Rexdale Boulevard, Etobicoke(Toronto), Ontario, M9W 1R3, Canada.Step 3—Combustion and Ventilation Air• US: Section 8.3 of the NFGC, Air for Combustion andVentilation• CANADA: Part 7 of the NSCNGPIC, Venting Systems and AirSupply for AppliancesStep 4—Duct Systems• US and CANADA: Air Conditioning Contractors Association(ACCA) Manual D, Sheet Metal and Air Conditioning Con-tractors National Association (SMACNA), or American Soci-ety of Heating, Refrigeration, and Air Conditioning Engineers(ASHRAE) 2001 Fundamentals Handbook Chapter 34.Fig. 3—Clearances to CombustiblesA04110This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size furnaces are only approved for altitudes 0 - 7,000 ft.(0 - 2,135m).An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications.This furnace is for indoor installation in a building constructed on site. This furnace may be installed in a manufactured (mobile) home when stated on rating plate andusing factory authorized kit..This furnace may be installed on combustible flooring in alcove or closet at Minimum Inches Clearance To Combustible Construction as described below.This furnace requires a special venting system. Refer to the installation instructions for parts list and method of installation. This furnace is for use with schedule-40 PVC,PVC-DWV, CPVC, or ABS-DWV pipe, and must not be vented in common with other gas-fired appliances. Construction through which vent/air intake pipes may beinstalled is maximum 24 inches (600 mm), minimum 3/4 inches (19 mm) thickness (including roofing materials).MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION* Minimum front clearance for service 24 inches (610mm).140 size furnaces require 1 inch back clearance to combustible materials.For installation on combustible floors only when installed on special base No. KGASB0201ALL,Coil Assembly, Part No. CD5 or CK5, or Coil Casing, Part No. KCAKC.Line contact is permissible only between lines formed by intersections of top and two sides offurnace jacket, and building joists, studs, or framing.Clearance shown is for air inlet and air outlet ends.120 and 140 size furnaces require 1 inch bottom clearance to combustible materials.ØClearance in inchesDégagement (po).Vent clearance tocombustibles 0".0 (po) Dégagementd´évent avec combustibles.Dégagement avant minimum de 610mm (24 po) pour l´entretien.Pour les fournaises de 140 taille, 1 po (25mm) dégagement des matériaux combustibles estrequis au-arriere.This furnace is approved for UPFLOW, DOWNFLOW andHORIZONTAL installations.Cette fournaise est approuvée pour l´installation HORIZONTALEet la circulation d´air VERS LE HAUT et VERS LE BAS.*BOTTOMDESSOUS0"Ø3"0"§0"TOP/PLENUMDESSUS/CHAMBRE D´AIR1"0" §24MINALL POSITIONS:DOWNFLOW POSITIONS:IHORIZONTAL POSITIONS::S I D EC O T E S F R O N TA V A N TBC KA R R I EAERS E R VI ECL ÈNTR TENEIVA NA TF RON TS I D EC O T E SF OUUF R N A CSEEIAR NLes fléches de dégagementne change pas avecl´orientation de lagénérateur d´air chaud.Clearance arrowsdo not change withfurnace orientation.††††UPFLOW ORDOWNFLOWFRONT FRONTLEVEL (0") TO1/2" MAX† †INSTALLATION†POUR LA POSITION HORIZONTALE:POUR LA POSITION COURANT DESCENDANT:POUR TOUS LES POSITIONS:UØ*§§For upflow and downflow applications, furnace must be installed level, or pitched within 1/2" of level. For ahorizontal application, the furnace must be pitched minimum 1/4" to maximum of 1/2" forward for properdrainage. See Installation Manual for IMPORTANT unit support details on horizontal applications.HORIZONTALDÉGAGEMENT MINIMUM EN POUCES AVEC ÉLÉMENTS DE CONSTRUCTION COMBUSTIBLES† †Pour l´installation sur le plancher combustible seulement quand on utilise la base spéciale, piècenº KGASB0201ALL, l´ensemble serpentin, pièce nº CD5 ou CK5, ou le carter de serpentin,pièce nº KCAKC.Le contact n´est permis qúentre les lignes formées par les intersections du dessus et desdeuxcôtés de la chemise de la fournaise, et des solives, des montants ou de la charpente dubátiment.La distance indiquée concerne l´extrémité du tuyau d´arrivée d´air et l´extrémité du tuyau de sortied´air.Pour les fournaises de 120 et 140 taille, 1 po (25mm) dégagement des matériaux combusitblesest requis au-dessous.MIN 1/4" TO 1/2" MAXCette fournaise à air pulsé est équipée pour utilisation avec gaz naturel et altitudes comprises entre 0 - 3,050m (0 - 10,000 pi),excepté queles fournaises de 140 taillesont pour altitudes comprises entre 0 - 2,135m (0 - 7,000pi).Utiliser une trousse de conversion, fournie par le fabricant, pour passer au gaz propane ou pour certaines installations au gaz naturel.Cette fournaise à air pulsé est pour installation à l´intérieur dans un bâtiment construit sur place. Cette fournaise à air pulse peut être installée dans une maisonpréfabriquée (maison mobile) si prescrit par la plaque signalétique et si l' on utilise une trousse specifiée par le fabricant.Cette fournaise peut être installée sur un plancher combustible dans un enfoncement ou un placard en observant les Dégagement Minimum En Pouces AvecÉléments De Construction Combustibles.Cette fournaise nécessite un système d´évacuation spécial. La méthode d´installation et la liste des pièces nécessaires figurent dans les instructions d´installation. Cettefournaise doit s´utiliser avec la tuyauterie des nomenclatures 40 PVC, PVC-DWV, CPVC, ou ABS-DWV et elle ne peut pas être ventilée conjointment avec d´autresappareils à gaz. Épaisseur de la construction au travers de laquelle il est possible de faire passer les tuyaux d'aération (admission/évacuation): 24 po (600 mm)maximum, 3/4 po (19mm) minimum (y compris la toiture).Pour des applications de flux ascendant et descendant, la fournaise doit être installée de niveau ou inclinée àpas plus de 1/2" du niveau. Pour une application horizontale, la fournaise doit être inclinée entre minimum1/4" et maximum 1/2" du niveau pour le drainage approprié. En cas d´installation en position horizontale,consulter les renseignements IMPORTANTS sur le support dans le manuel d´installation.328066-201 REV. B LIT TOP4→→