777. Install the remaining manifold mounting screws.8. Check the igniter alignment. See Fig. 62, 63 and 68.9. Attach the wires to the roll-out switches.10. Align the burner assembly with the openings in the primarycell inlet panel and attach the burner assembly to the cellpanel.11. Connect the wire for the flame sensor.12. Connect the wire for the Hot Surface Igniter.NOTE: Use propane-resistant pipe dope to prevent leaks. Do notuse Teflon tape.13. Install the gas pipe to the gas valve.FIRE OR EXPLOSION HAZARDFailure to follow this warning could result in personalinjury, death, and/or property damage.Never purge a gas line into a combustion chamber. Nevertest for gas leaks with an open flame. Use a commerciallyavailable soap solution made specifically for the detectionof leaks to check all connections. A fire or explosion mayresult causing property damage, personal injury or loss oflife.! WARNING14. Check for gas leaks with a commercially available soapsolution made specifically for the detection of leaks.15. Turn gas on at electric switch on gas valve and at externalshut-off or meter16. Turn power on at external disconnect, fuse or circuit break-er.17. Run the furnace through two complete heating cycles tocheck for proper operation18. Install control door when complete.Servicing Hot Surface IgniterThe igniter does NOT require annual inspection. Check igniterresistance before removal. Refer to Fig. 62, 63 and 68.1. Turn off gas and electrical supplies to furnace.2. Remove control door.3. Disconnect igniter wire connection.4. Check igniter resistance. Igniter resistance is affected bytemperature. Only check resistance when the igniter is atroom temperature.a. Using an ohm meter, check resistance across both igniterleads in connector.b. Cold reading should be between 40 ohms and 70 ohms.5. Remove igniter assembly.a. Using a 1/4--in. driver, remove the two screws securing theigniter mounting bracket to the burner assembly See Fig.68.b. Carefully withdraw the igniter and bracket assemblythrough the front of the burner assembly without strikingthe igniter on surrounding parts.c. Inspect igniter for signs of damage or failure.d. If replacement is required, remove the screw that securesthe igniter on igniter bracket and remove the igniter.6. To replace igniter and bracket assembly, reverse items 5athrough 5d.7. Reconnect igniter harness to the igniter, dressing the igniterwires to ensure there is no tension on the igniter itself. SeeFig. 68.8. Turn on gas and electrical supplies to furnace.9. Verify igniter operation by initiating control board self--testfeature or by cycling thermostat.10. Replace control door.Flushing Collector Box and Drainage SystemELECTRICAL SHOCK AND FIRE HAZARDFailure to follow this warning could result in personal injury,death, and/or property damage.Turn off the gas and electrical supplies to the furnace andinstall lockout tag before performing any maintenance orservice. Follow the operating instructions on the labelattached to the furnace.! WARNING1. Turn off gas and electrical supplies to furnace.2. Remove control door.3. Disconnect pressure switch tube from pressure switch port.NOTE: Ensure the pressure switch tube disconnected from thepressure switch is higher than the collector box opening or waterwill flow out of tube.4. Remove the collector box plug from the top port on the up-per corner of the collector box. See Fig. 64.5. Attach a funnel with a flexible tube to port on the collectorbox.6. Flush inside of collector box with water until dischargewater from condensate trap is clean and runs freely.7. Repeat steps 4 thru 6 with middle plug on upper corner ofcollector box.8. Remove the pressure switch tube from the collector box.NOTE: Do NOT blow into tube with tube connected to thepressure switch.9. Clean pressure switch port on collect box with a small wire.Shake any water out of pressure switch tube.10. Reconnect tube to pressure switch and pressure switch port.11. Remove the relief tube from the port on the collector boxand the trap.12. Clean the relief port on collect box and the trap with a smallwire. Shake any water out of the tube.13. Reconnect relief tube to trap and collector box ports.Cleaning Condensate Drain and TrapNOTE: If the condensate trap is removed, a new gasket betweenthe trap and collector box is required. Verify a condensate trapgasket is included in the service kit or obtain one from your localdistributor.1. Disconnect power at external disconnect, fuse or circuitbreaker.2. Turn off gas at external shut-off or gas meter.3. Remove control door and set aside.4. Turn electric switch on gas valve to OFF.5. Disconnect external drain from condensate drain elbow ordrain extension pipe inside the furnace and set aside.6. Disconnect the condensate trap relief hose from collectorbox port and condensate trap.NOTE: If condensate has a heat pad attached to the trap, trace thewires for the pad back to the connection point and disconnect thewires for the heat pad.7. Remove the screw that secures the condensate trap to thecollector box, remove the trap and set aside.8. Remove the trap gasket from the collector box if it did notcome off when the trap was removed.9. Discard the old trap gasket.10. Rinse condensate trap in warm water until trap is clean.11. Flush condensate drain lines with warm water. Rememberto check and clean the relief port on the collector box.12. Shake trap dry.13. Clean port on collector box with a small wire.59SC2C