T-359 4–46Table 4–9 DataCORDER Pre-trip Result RecordsTEST # TITLE DATA1-0 Heater On Pass/Fail/Skip Result, Change in current for Phase A, B and C1-1 Heater Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C2-0 Condenser Fan On Pass/Fail/Skip Result, Water pressure switch (WPS) - Open/Closed, Change in currents for Phase A, B and C2-1 Condenser Fan Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C3-0 Low Speed Evaporator Fan On Pass/Fail/Skip Result, Change in currents for Phase A, B and C3-1 Low Speed Evaporator Fan Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C4-0 High Speed Evaporator Fan On Pass/Fail/Skip Result, Change in currents for Phase A, B and C4-1 High Speed Evaporator Fan Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C5-0 Supply/Return Probe Test Pass/Fail/Skip Result, STS, RTS, SRS and RRS5-1 Secondary Supply Probe (SRS) Test Pass/Fail/Skip5-2 Secondary Return Probe (RRS) Test Pass/Fail/Skip6-0 Discharge Thermistor Test Pass/Fail/Skip6-1 Suction Thermistor Test Pass/Fail/Skip6-2 Discharge Pressure Sensor Test Pass/Fail/Skip6-3 Suction Pressure Sensor Test Pass/Fail/Skip6-4 Compressor Current Draw Test Pass/Fail/Skip6-5 Compressor Leak Test Pass/Fail/Skip6-6 Economizer Valve Test Pass/Fail/Skip6-7 Digital Unloader Valve Test Pass/Fail/Skip7-0 High Pressure Switch Closed Pass/Fail/Skip Result, AMBS, DPT or CPT (if equipped)Input values that component opens7-1 High Pressure Switch Open Pass/Fail/Skip Result, STS, DPT or CPT (if equipped)Input values that component closes8-0 Perishable Mode Heat Test Pass/Fail/Skip Result, STS, time it takes to heat to 16C (60F)8-1 Perishable Mode Pulldown Test Pass/Fail/Skip Result, STS,time it takes to pull down to 0C (32F)8-2 Perishable Mode Maintain Test Pass/Fail/Skip Result, Averaged DataCORDER supplytemperature (SRS) over last recording interval.9-0 Defrost Test Pass/Fail/Skip Result, DTS reading at end of test, line voltage,line frequency, time in defrost.10-0 Frozen Mode Heat Test Pass/Fail/Skip Result, STS, time unit is in heat.10-1 Frozen Mode Pulldown Test Pass/Fail/Skip Result, STS,time to pull down unit to -17.8C (0F).10-2 Frozen Mode Maintain Test Pass/Fail/Skip Result, Averaged DataCORDERreturn temperature (RRS) over last recording interval.