3210 - MAIN OPTIONSOptions No. Description Advantages UseCorrosion protection,traditional coils 2B Factory application of Blygold Polual treatmenton the copper/aluminium coilsImproved corrosion resistance, recommendedfor industrial, rural and marine environments30XAS242-482Corrosion protection,traditional coils 3A Fins made of pre-treated aluminium(polyurethane and epoxy)Improved corrosion resistance, recommendedfor moderate marine and urban environments30XAS242-482Unit equipped for airdischarge ducting 10 Fans equipped with discharge connectionflanges - maximum available pressure 60 Pa Facilitates connections to the discharge ducts 30XAS242-482IP54 control box 20A Increased leak tightness of the unitProtects the inside of the electrical box fromdusts, water and sand. In general this option isrecommended for installations in pollutedenvironments30XAS242-482Grilles and enclosure panels 23 Metal grilles on the 4 unit sides, plus sideenclosure panels at each end of the coilImproves aesthetics, protection againstintrusion to the unit interior, coil and pipingprotection against impacts.30XAS242-482Enclosure panels 23A Side enclosure panels at each end of the coil Improves aesthetics, coil and piping protectionagainst impacts.30XAS242-482Winter operation down to-20 °C 28 Fan speed control via frequency converter Stable unit operation for air temperature downto -20 °C30XAS242-482Evaporator frost protection 41A Electric resistance heater on the evaporatorand discharge valveEvaporator frost protection down to -20 °Coutside temperature30XAS242-482Evap.and hydraulic mod.frost protection 41B Electric resistance heater on evaporator,discharge valve and hydraulic moduleEvaporator and hydraulic module frostprotection down to -20 °C outside temperature30XAS282-482Total heat recovery 50 Unit equipped with additional heat exchanger inparallel with the condenser coils.Production of free hot-water simultaneouslywith chilled water production30XAS242-482Master/slave operation 58Unit equipped with supplementary water outlettemperature sensor kit to be field-installedallowing master/slave operation of two unitsconnected in parallelOptimised operation of two units connected inmaster/slave operation operating timeequalisation30XAS242-482Service valve set 92Liquid line valve (evaporator inlet), compressorsuction and discharge line valves andeconomiser line valveAllow isolation of various refrigerant circuitcomponents for simplified service andmaintenance30XAS242-482Compressor dischargevalves 93A Shut-off valve on the compressor dischargepiping Simplified maintenance 30XAS242-482HP dual-pump hydraulicmodule 116CComplete hydraulic module equipped withwater filter, expansion tank with relief valve, twohigh pressure pumps, drain valve and waterflow control valve. For more details, refer to thededicated chapterEasy and fast installation (plug & play).Increased system reliability30XAS282-482High energy efficiency 119Higher air flow through the condenser coilsimproving heat exchange efficiency on thecondenserEnergy cost reduction and extended operatingenvelope (full load operation at higher airtemperature)30XAS242-482J-Bus gateway 148B Two-directional communication boardcomplying with JBus protocolConnects the unit by communication bus to abuilding management system30XAS242-482Lon gateway 148D Two-directional communication boardcomplying with Lon Talk protocolConnects the unit by communication bus to abuilding management system30XAS242-482Bacnet over IP 149Two-directional high-speed communicationusing BACnet protocol over Ethernet network(IP)Easy and high-speed connection by ethernetline to a building management system. Allowsaccess to multiple unit parameters30XAS242-482Energy ManagementModule 156Control board with additional inputs/outputs.See Energy Management Module optionchapterExtended remote control capabilities (Set-pointreset, ice storage end, demand limits, boiler on/off command...)30XAS242-482Touch Pilot control, 7" userinterface 158A Touch Pilot control supplied with a 7 inch colourtouch screen user interface Enhanced ease of use. 30XAS242-482Leak detection 1590-10 V signal to report any refrigerant leakagein the unit directly on the controlller (the leakdetector itself must be supplied by thecustomer)Immediate customer notification of refrigerantlosses to the atmosphere, allowing timelycorrective actions30XAS242-482Dual relief valves installedw/ 3-way valve 194 Three-way valve upstream of the relief valveson the evaporator and the oil separatorValve replacement and inspection facilitatedwithout refrigerant loss. Comforms to Europeanstandard EN378/BGVD430XAS242-482Compliance with Russianregulations 199 EAC certification Conformance with Russian regulations 30XAS242-482Compliance with Australianregulations 200 Unit approved to Australian code Conformance with Australian regulations 30XAS242-482Power factor correction 231 Capacitors for automatic regulation of powerfactor (cos phi) value to 0,95.Reduction of the real electrical power,compliance with minimum power factor limit setby utilities30XAS242-482