Carrier B6 Series Specification
Toxic/Combustible Gas Transmitter B6SpecificationN2-B6 Series - 8/23/23Specifications subject to change without notice.Catalog No. 11-808-788-01 Page 1 of 16OverviewThe B6 Series Toxic/Combustible Gas Detectors use various sensing technologies todetect a wide assortment of gases. These units are housed in a NEMA 4X rated plasticenclosure that will meet a wide variety of applications. The combo unit consists of amain unit (Carbon Monoxide only) with an LCD, LED status indication, 3 userconfigurable relays and a remote sensing unit (various gas types available) forinstallation at high or low elevations based on the density of the gas being detected.The main and remote unit gas concentrations levels are both displayed on the mainunit’s LCD. This series also features a sensor module that can be easily replaced byremoving a couple of screws and unplugging the existing module before inserting thenew factory calibrated sensing module. All units should be verified for properfunctionality and calibration once the replacement sensor module has been reinstalled.A user selectable password can be used to protect the system integrity.Applications: Mechanical Rooms, Warehouses, Refrigeration Plants, Industrial Plants,Process Monitoring, Leak Detection, Parking Garages, Auto/Truck MaintenanceFacilities, Oil and Gas IndustryCautionIt is your responsibility to ensure that the B6 Series will meet all of your applicable Federal, State,Provincial and Local Health and Safety laws and regulations before using these products.The B6 Series Gas Transmitters are covered by a Two (2) Year Limited Warranty against defects in material andworkmanship from the date of shipment with the exception of the Sensor Modules (Electrochemical/Toxic: Six Months andCatalytic/ Combustible: One Year)Part NumbersN2-B6-CO/NO2-10PSpecificationsSupply Voltage: VDC Supply Voltage: 24 VDC nominal (+18 to 30 VDC)VAC Supply Voltage: 24 VAC nominal (+15 to 24 VAC) (AC Power must not be grounded)Fuse Protection: 0.750A Polyswitch; (Resets after fault is cleared & power to circuit is removed)Supply Current | PowerConsumption: 0.3A maximum | 8.4 VACommunication Protocols: RS-485 Serial BACnetTM MS/TP (Master and Slave; Default: Master)B6 Communication Baud Rates: 9600, 19200, 38400, 76800 Bits/Second (Default: 38400)Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheetDisplay: LCD Graphic Display with backlight (Displays: TWA, STEL and Concentration)Keypad Three Capacitive Touch sensing keysRelays | Contact Type | RelayContact Ratings:Three | SPDT (Form C) Dry Contacts | 1.0A max. @ 30 VDC or 0.3A max. @ 125 VAC(Resistive Loads) |
Related manuals for Carrier B6 Series
manualsdatabase
Your AI-powered manual search engine