8Timer ON and Timer OFFSET TEMP.C L O C KSPEED AUTOAUTOTIMER OFFTIMER ONA08041Use both functions to program the unit to turn on and shut off atspecified times.UNIT OFF-- Set TIMER ON as previously described.-- Set TIMER OFF as previously described.-- The unit will start automatically at the set TIME ON and willturn off at the set TIME OFF.UNIT ON-- Set TIME OFF as previously described.-- Set TIME ON as previously described.-- The unit will turn off automatically at the set TIME OFFand will turn on at the set TIME ON.Sleep ModeThis mode is used to conserve energy and can be used when theunit is in the COOL, HEAT or AUTO mode only.Cool Mode-- Push the SLEEP button. The SLEEP display will appear onthe remote control.SET TEMP.C L O C KSPEED AUTOCOOLA08038-- After 1 hour the set point will be raised by 1.8_F (1_C).-- After another hour, the set point will be raised by another1.8_F (1_C) and the fan will run in low speed.-- The unit will shut off 7 hours after setting the SLEEP mode.-- The SLEEP mode will be cancelled if any button on theremote control is pressed.Heat Mode-- Same as cooling mode but set points will be lowered by1.8_F (1_C).Turbo ModeThis function is available in COOL mode on 9k and 12k coolingonly units. Use the TURBO mode to cool the room rapidly.-- Press the TURBO button. An audible “beep” will be heard.-- The fan will run on high speed.-- The TURBO mode terminates automatically after 20 minutesfrom pushing the Turbo mode button once. It can beterminated immediately by pushing the Turbo mode again.When the Turbo mode is terminated, the unit will go back tothe original setting.LockUse this function to lock the settings on the remote control and toprevent the settings being changed.SET TEMP.C L O C KSPEED AUTOCOOLLOCK SYMBOLA08039To lock and unlock the remote control, press the Y and B tempbuttons simultaneously for about 3 seconds.Resetting the Remote ControlIf the remote control is not functioning properly, it can be reset bypressing the reset button with a paper clip or tip of a pen. Currentsettings will be cancelled and the control will return to the initialsettings and will be in standby mode. Push the ON/OFF buttonto activate it.Time DelayIf the On/Off button is pressed too soon after a stop, thecompressor will not start for 3 minutes due to the inherentprotection against frequent compressor cycling. The unit will onlyemit an audible beep when the signals are received correctly.Heating FeaturesIf the unit is in the heating mode, there will be a delay when thefan starts. The fan will start only after the coil is warmed up toprevent cold blow.Defrost OperationIn heating mode, if the outdoor coil is frosted, the indoor fan andoutdoor fan will turn off while system removes the frost on theoutdoor coil.The system will automatically revert to normal operation whenfrost is removed from the outdoor unit.Auto StartIf the power fails while the unit is operating, the unit stores theoperating condition, and it will start operation automatically underthose conditions when the power is restored.