Carrier EVERGREEN 19XR Installation And Start-up Instructions Manual
Also see for Evergreen 19XR: Product data
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Catalog No. 04-53190018-01 Printed in U.S.A. Form 19/23-2SI Pg 1 6-11 Replaces: 19/23-1SIInstallation and Start-Up InstructionsPart No: 33CNTVIEWCONTENTSSAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1ABBREVIATIONS AND EXPLANATIONS . . . . . . . . . . 1PACKAGE CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 1CHILLER SOFTWARE VERSIONREQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,2INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4Equipment Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Step 1 — Identify Power Supply . . . . . . . . . . . . . . . . . . 2Step 2 — Assemble Swing Arm . . . . . . . . . . . . . . . . . . 2Step 3 — Attach Arm to Tube Sheet . . . . . . . . . . . . . . 2Step 4 — Mount Display Screen on ArmMounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Step 5 — Connect Cable Between Display andICVC (International Chiller Visual Control) . . . . . . 4START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10Start Touch Screen System . . . . . . . . . . . . . . . . . . . . . . 4Start Carrier Network Manager . . . . . . . . . . . . . . . . . . . 5Configure ComfortVIEW™ Software on TouchScreen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5SAFETY CONSIDERATIONSWhen installing this accessory, observe precautions in theliterature and on any labels attached to the equipment, and allother safety precautions that may apply.• Follow all safety codes.• Use care in handling and installing this accessory.INTRODUCTIONCarrier's new EverVu™ touch screen display allows a facil-ity manager to monitor a chiller from a 15-in. color touchscreen display. The EverVu display screens allow easy naviga-tion to determine data and chiller trends such as a chiller per-formance trend, chilled water trend, condenser water trend andpower trend. The EverVu touch screen display is available forEvergreen 19XR, 19XRV and 23XRV chillers and 32 Serieschiller retrofit packages. The display is provided with Comfort-VIEW™ software preloaded.Retrofit Compatibility — The EverVu™ display canbe retrofitted to any existing Carrier Comfort Network® (CCN)compatible chiller, though default screen sets may not beincluded for all chillers. The display may also be retrofitted tocompetitor’s chillers when the 32 Series retrofit panels areapplied.ABBREVIATIONS AND EXPLANATIONSTerms and abbreviations used in this manual include:PACKAGE CONTENTS• Touch screen display screen with quick connect mount• Swing arm for mounting (assembly required; see SwingArm Assembly Instructions)• RS-232 to RS-485 converter from B&B Electronics• ComfortVIEW software key (USB) (already installed inback side of display screen)• Several bags containing bolts and Allen style wrenches• Touch computer power supply• 6-ft or 25-ft Beldon power cable (25-ft cable will beavailable for order)• 25-ft coiled communication cable with RJ-14 connectors• Swing Arm Assembly InstructionsCHILLER SOFTWARE VERSION REQUIRE-MENTSThe chiller software in the International Chiller Visual Con-trol (ICVC) controller must match a version of chiller softwarefor which the EverVu workspace screens have been developed.The EverVu display is supplied with databases to support thechiller software versions listed in Table 1.Table 1 — Chiller Software Version RequirementsWARNINGElectrical shock can cause personal injury and death. Shutoff all power to this equipment during installation. Theremay be more than one disconnect switch. Tag all discon-nect locations to alert others not to restore power until workis completed.CCN (CarrierComfort Network)— Carrier’s proprietary communicationsprotocolCCN bus — 3-wire RS-485 network for CCN elementsCCN element — Unique addressing scheme for deviceson a CCN networkNetwork Manager — ComfortVIEW software system formanaging network devicesWorkspaceManager— ComfortVIEW software for managingviewspaces and trends withinworkspaces for graphical representationof a systemUNIT EVERVU DATABASEVERSIONCHILLERSOFTWAREVERSION19XR 19XR Version 09 Chiller CESR-131294-0919XRV 19XRV Version 04 Chiller CESR-131350-0423XRV 23XRV Version 02 Chiller CESR-131293-0232DK 19DK Version 01 Chiller(Build 0.016) CESR-131458-0132XR 32XR Version 01 Chiller CESR-131435-01EVERVU™ Touch Screen Display forEVERGREEN ® 19XR,XRV, 23XRV Chillerswith PIC II or PIC III Controls |
Related manuals for Carrier Evergreen 19XR
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine