SYSTXCCUIZ01-- VInfinityt ControlInstallation InstructionsHOLD COOLHEATOFFZONEI NFINITY ™S YSTEMA04031Fig. 1 -- Infinityt Zone ControlNOTE: Read the entire instruction manual before starting theinstallation.TABLE OF CONTENTSPAGESAFETY CONSIDERATIONS 1. . . . . . . . . . . . . . . . . . . . . . . . .INTRODUCTION 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .INSTALLATION AND START--UP OVERVIEW 2. . . . . . . . . .INSTALLATION 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .INSTALLING INFINITY ZONE CONTROL 4. . . . . . . . . . . . . .INITIAL POWER--UP 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .QUICK START 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .INSTALL / SERVICE MENUS 9. . . . . . . . . . . . . . . . . . . . . . . . .EQUIPMENT SUMMARY MENU 9. . . . . . . . . . . . . . . . . . . . . .INSTALL MENU 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SETUP MENU 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CHECKOUT MENUS 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SERVICE MENUS 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OPERATIONAL INFORMATION 16. . . . . . . . . . . . . . . . . . . . .TROUBLESHOOTING 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SYSTEM MALFUNCTION SCREEN 20. . . . . . . . . . . . . . . . . .SAFETY CONSIDERATIONSImproper installation, adjustment, alteration, service, maintenance,or use can cause explosion, fire, electrical shock, or otherconditions which may cause death, personal injury or propertydamage. Consult a qualified installer, service agency or yourdistributor or branch for information or assistance. The qualifiedinstaller or agency must use factory--authorized kits or accessorieswhen modifying this product. Refer to the individual instructionspackaged with the kits or accessories when installing.Follow all safety codes. Wear safety glasses, protective clothing,and work gloves. Have a fire extinguisher available. Read theseinstructions thoroughly and follow all warnings and cautionsincluded in literature and attached to the unit. Consult localbuilding codes and the current edition of the National ElectricalCode (NEC) NFPA 70.In Canada, refer to the current editions of the Canadian ElectricalCode CSA C22.1.Recognize safety information. When you see this symbol onthe unit and in instructions or manuals, be alert to the potential forpersonal injury. Understand the signal words DANGER,WARNING, and CAUTION. These words are used with thesafety--alert symbol. DANGER identifies the most serious hazards,which will result in severe personal injury or death. WARNINGsignifies hazards, which could result in personal injury or death.CAUTION is used to identify unsafe practices, which may resultin minor personal injury or product and property damage. NOTEis used to highlight suggestions which will result in enhancedinstallation, reliability, or operation.INTRODUCTIONThe Infinity Zone System consists of several intelligentcommunicating components which includes the Infinity ZoneControl (or User Interface), Smart Sensors, Damper ControlModule, variable speed furnace or FE fan coil, 2--stage AC or HPand Infinity Packaged Products, which continually communicatewith each other via a four--wire connection called the ABCD bus.Commands, operating conditions, and other data are passedcontinually between components over the ABCD bus. The result isa new level of comfort, versatility, and simplicity.All Infinity furnaces or fan coils are variable--speed andmulti--stage for maximum flexibility, efficiency, and comfort. Theysupport controlled ventilation, humidification, dehumidification,and air quality control. Either an Infinity (communicating) or astandard 24VAC controlled outdoor unit may be used.When using conventional outdoor units, the Infinity furnace or fancoil provides the 24 volt signals needed to control them. Also, theInfinity Damper Control Module (P/N SYSTXCC4ZC01) allowsconnection of a Carrier HRV or ERV without the need for aseparate wall control.All system components are controlled through the wall mountedInfinity Zone Control, which replaces the conventional thermostatand provides the homeowner with a single wall control for allfeatures of the system.