8Solid Piece Wood(If required)A06542Fig. 13 --- Solid Piece of Wood PlacementWindow SashWindow SashSealing StripA06543Fig. 14 --- Seal Strip AdhesionStep 6 —Installation of the cabinetA. Align one hole in the bottom of the cabinet with one hole inthe bracket assembly. Secure the cabinet to the bracket using(3) 1/4” screws provided. Repeat the same procedure on theopposite side of the cabinet. See (Fig. 15).B. Ensure the ”L” shaped mounting channel is positioned in frontof the sash. The bottom channel of the cabinet should bepositioned in the track provided on the bracket assembly. Pullthe window down until it rests just behind the front of the ”L”shaped mounting channel. See (Fig. 16).C. Check to make sure that the cabinet is slanted slightlydownward on the outside. If necessary, re--adjust supportbracket as shown in (Fig. 12).Step 7 —Secure ShuttersA. Carefully slide the air conditioner back into the cabinet.(Please seek assistance for this procedure).B. Reinstall the slide--out--chassis security screws (removedearlier) on both sides of the cabinet (see Fig. 12). Secure thetop of the frames to the window sash with (2) 3/4” screws.C. Now, secure bottom frame of shutters using one shutter clampand one 3/4” screw on each side (see Fig. 12).Step 8 —Reinstalling Front Panel AssemblyA. Position the front panel on the cabinet starting at the top. Thefront panel lock tabs must be inserted into the retaining slots inthe cabinet. Repeat this procedure on all sides.B. Secure the front grille to the cabinet using the Philips screwsremoved earlier (see Fig. 6).Step 9 —Complete the installationA. Cut the foam to fit the opening between the top of the insideand outside window (see Fig. 18).B. Some installations may require additional sealing aroundthe window and air conditioner. Check for any air leaks andseal where necessary.C. In very humid areas, the water removal may be excessiveenough to overflow the unit or increase the noise of the airconditioner. If this occurs, you may wish to attach a drain hose(not included) to the drain plug allowing condensations to runoff conveniently (see Fig. 19).NOTE: Fresh Air ventilation is usually kept in the closedposition. Use only when clearing smoke and/or odors from theroom. Pull to open (see Fig. 20).1/4" ScrewsA06544Fig. 15 --- Secure the CabinetWindow Sash"L"ShapedMountingChannelSealA06545Fig. 16 --- Mounting ChannelCoil3/4" screwsSecurity Screw"L"ShapedMountingChannelSealFHRFANSPEEDMODEOFFON/TIMERAirc o nd itione rWAIT THREE MINUTESBEFORE RESTARTINGA06546Fig. 17 --- Security Screw DetailFoamA06547Fig. 18 --- Foam Fitting