— 10 — Initial Setting1. Connect an AC adaptor.2. Connect a Sustain pedal.NOTE: If there is no pedal or MIDI cable, pedal or MIDI check can be skipped. How to start diagnostic program1. Press the “POWER” button while pressing the “0” and “START/STOP” buttons.DIAGNOSTIC PROGRAMTESTSONG BANKMessage on LCDAD-5SP-23 OK sound must be audible with the display as Message on LCD3. ROM check1 Press “2” button.OK sound must ne audible.4. ROM Version check1 Press “1” button.Pip sound must be audible.5. D/A check1 Press “4” button.Minimum sine wave sound must be audible at center position.2 Press “5” button.Middle sine wave sound must be audible at center position.3 Press “6” button.Maximum sine wave sound must be audible at center position.OKSWITROM TEST↓ROM 0000↓ROM OK627Vr100MINMIDMAX Diagnostic program1. MODE Switch check1 Set to “CONCERT CHORD” position.2 Set to “FINGERED” position.3 Set to “NORMAL” position.2. SWITCH check1 Press “0” button.2 Press the buttons in the following order.TESTRHYTHTESTTONETESTSONG BANKSWITCH123 4895 6 73029282627251310111216 19 2214 17 20 2315 18 21 24