E-42Advanced programmings and registrationsTo change the settings on departmentsYou can program several settings such as restricting entry digits, prohibiting mul-tiple item registration, etc. on each department.Sample OperationSelectionsDept.1 ? Normal Dept. (A) V Maximum entry digits 4(B) Z Single item sales Dept.(C)Dept.2 Z Minus Dept. (A) B Maximum entry digits 5(B) ? Normal sales Dept. (C)• Minus Dept. is a department that entered unit prices are registered as minus price and is usedfor bottle return etc.• Single item sales Dept. registers one item quickly just by pressing a Dept. key once and youdon’t need to press p.Step Operation1 Press Ck to set the register in the program mode. Ck2 Enter your selection A, B, and C refering the following tables thenpress a Dept. key. The example on the right is setting Dept. 1 asNormal Dept. (A) limiting 4 digits (B), and Single item sales Dept.(C).?VZaA B C3 The example on the right is setting Dept. 2 as Minus Dept. (A) limit-ing 5 digits (B), and Normal sales Dept. (C).ZB?sA B C4 Press k to complete the settings. kSelectionsNormal Dept. ? AMinus Dept. ZMaximum seven digits manual price entry. ?BMaximum digit of manual price entry Z to NProhibit manual price entry < or >Normal sales Dept ? CSingle item Dept ZThe default settings: ???