GB752. Programme the device as follows3. ProgrammingProgramming enables the detectorto be recognised by the controlpanel.1. To programme the detector thecontrol panel must be ininstallation mode. If it is not, askthe user to press:then:master codeinstaller codeIMPORTANT: during recognitionprogramming, the product to beprogrammed for use with the controlpanel does not need to be placed nextto it. In fact, we recommend you placethe product at a short distance fromthe control panel (at least 2 metersaway).IMPORTANT: the control panel indicatesthere is an error by emitting 3 shortbeeps. When this happens programmingshould be carried out again.10 s max.Press ‹then # on thecontrol panelkeypadPressand hold the“test” buttonuntilthe controlpanelrespondsThe control panel waitsfor a group to be chosen(from 1 to 8). Choose thegroups by pressing thecorresponding numeralon the control panelkeypadThe control panel waitsfor the time delay to bechosen. 0: immediate1: delayed • 0: combined.The time delay is chosenby pressing “0” or “1” onthe control panel keypadThe controlpanel gives avoice messageto confirmthen to“détecteur X” “group?” “time delay?” “beep, detector X,group Y immediate(or delayed orcombined)”Example: programming of 1st detector allocated to Gr. 2 with immediate triggering.10 s max.))))then“detector 1” “group?” “time delay?” “beep, detector 1group 2,immediate”to* according tothe model of thecontrol panel.*)))))