1.1 Anchor Design and ApplicationThe Anchor on the Go™ Portable Roof Anchor for Metal Roofs has beendesigned and tested to 15kN and is therefore rated as a single person fallarrest anchor under AS/NZS1891.4. It is only suitable for use on roofsconstructed with metal roof sheeting with a minimum BMT of 0.42mmin the following profiles – Custom Orb, Trimdek, Spandek and Klip-Lok406 & Klip-Lok 700 provided ridge-capping is secured in place with roofscrews per manufacturer’s instructions.IMPORTANT: The Anchor on the Go™ Portable Roof Anchor is NOTsuitable for tiled, shingled, aluminium sheet, asbestos or decramasticroofs.IMPORTANT: This anchor is designed to be attached to the oppositeside of the roof from where you intend to work. Do NOT connect to or usethe anchor on the same side of the roof where the anchor is connected.If a second person is required to work on the roof, a second anchordevice must be used. Connecting two lines to a single anchorage device isNOT permitted. Where two connecting devices are attached to the sameanchorage point (e.g. two snap hooks), the snap hooks may rub againsteach other, causing them to be entangled or even become disengagedfrom the anchorage device.Additionally, testing has concluded that whilst this device can sustain aload of 22kN, the roof sheeting profiles most commonly used in Australiaand New Zealand will not sustain a static load greater than 15kN.IMPORTANT: Do NOT work outside an arc of 30 degrees either side ofthe centre line of the anchorage location to reduce the danger of swingfall hazards - refer to Figure One over the page.The user of this Anchor on the Go™ Portable Roof Anchor shall betrained and ensure that care is taken to adjust the safety line length sothat he/she will not be able to fall off the ends of the roof.IMPORTANT: Anchor on the Go™ Portable Roof Anchor is NOT suitablefor use as an anchorage device for a Temporary Horizontal Life Line.4