INSTALLATION INSTRUCTIONS10Power Requirements:120 VAC, 60 Hz., single phase.CT-304/CT-365: 0.10 Amp. Max.(Use 15 Amp. circuit minimum) Always disconnect the electric supply cord from the wall outlet or turn off the electricity at theservice disconnect before servicing this appliance. Observe all governing codes and ordinances when grounding, in the absence of which, observeNational Electrical Code ANSI/NFPA No. 70-1990.Recommended Grounding Method:This appliance is factory equipped with a power supply cord with a three-prong grounding plug (withpolarized parallel blades). It must be plugged into a mating grounding-type receptacle, connected toa correctly polarized 120 Volt circuit. If the circuit does not have a grounding type receptacle, it is theresponsibility and obligation of the installer or user to have the existing receptacle changed to aproperly grounded and polarized receptacle in accordance with all applicable local codes andordinances by a qualified electrician. In the absence of local codes and ordinances, the receptaclereplacement shall be in accordance with the National Electrical Code. THE THIRD GROUND PRONGSHOULD NOT, UNDER ANY CIRCUMSTANCES, BE CUT OR REMOVED. The electrical supply must be a120 volt, 60 Hz single phase, 15 AMP circuit. The power receptacle must be a NEMA 5-15R device toaccept the three prong plug supplied with the unit.THIRD GROUND PRONGCOUNTER TOPGAS SUPPLYInstaller suppliedshut-off valve mustbe easily accessibleinside cabinetryELECTRIC SUPPLY4 FOOT POWER CORDCOUNTER TOPGAS SUPPLYInstaller suppliedshut-off valve mustbe easily accessibleinside cabinetryELECTRIC SUPPLY4 FOOT POWER CORD90 0 Elbowsupplied*(CT-304only)• Required when unit is installed over Wall OvenREGULATOR REGULATORGAS CONNECTION FOR CT-365 GAS CONNECTION FOR CT-304