7WOS-127 & 130 SINGLE WALL OVENSThe WOS-127 and WOS-130 single ovens may be installed below the DCS CT-365 gas cooktop in astandard 36” tall (to counter surface) base cabinet. Refer to diagram shown below for cabinet andcountertop cutout dimensions.The gas shut-off valve and power supply receptacle for the cooktop must remain accessible from thefront after the units are installed. It is suggested that the valve and receptacle be located in thecabinet adjacent to the wall oven on the right. To prevent interference with the wall oven chassis, thecooktop gas regulator must be mounted at the shut-off valve. Use approved flexible gas tubing tomake the connection between the regulator and the cooktop.Install the cooktop into the countertop first. Make the connections to the gas and power supplies asper the cooktop installation instructions. Verify that the electrical service to the oven is shut off. Makethe power supply connections for the wall oven and then slide the unit into the cabinet. Secure unitto cabinet as noted in “Mounting the Wall Oven” section. Turn on all utilities and check both units forproper operation.WARNING:When pushing wall oven into cabinet, be careful not to pinch the gasconnection to the cooktop.Min.Cabinet Face19-3/4"34-3/4"1-1/2"4-3/4"25-1/2"28-5/16"+ 1/16"- 0"(27" Oven)28-1/2" (30" Oven)36"24"UNDER COUNTER INSTALLATION WITH CT-365