17Gas ConnectionWARNINGMake sure the gas supply valve is off and that the power to•the range is turned off at the circuit breaker or fuse box priorto connecting the gas line.Do not apply excessive pressure when tightening gas•connections and fittings.Do not use Teflon tape or plumber’s putty on gas flex line•connections.Check for gas leaks as instructed below before using the•appliance. Do not use a flame to check for leaks.For LP installations, the LP gas tank must have its own•high pressure regulator. This is in addition to the pressureregulator provided with the range.The maximum gas supply pressure to the regulator must•never exceed 1/2 pound per square inch (p.s.i.) or 3.5kPa.The range and shut-off valve must be disconnected from the•gas supply piping during any pressure testing exceeding 1/2p.s.i. (3.5 kPa).The range must be isolated from the gas supply piping by•closing the shut-off valve during any pressure testing at orbelow 1/2 p.s.i. (3.5 kPa).Be careful not to damage the wires inside the chassis while•pushing the gas line through the access holes.NOTE: The gas pressure regulator is pre-set at the factory forthe type of gas intended for use with the appliance. To verify thatthe appliance is compatible with the type of gas available, checkthe range rating label (see page 3 for location). Ranges intendedfor use with LP gas will have “LP” as a part of the model number.Consult your dealer if the range is not compatible with the type ofgas supplied.Make sure the gas supply valve is in the off position and1.power to the range is off.Connect a flexible gas supply line to the gas shut-off valve2.previously installed on the stub out. The gas line needs to belong enough to allow the range to be pulled out for service.Slide the gas line up through the access holes in the chassis3.and up to the regulator. Move the wires around inside theaccess holes to prevent them from catching on the gas lineas you push it up.Connect the gas line to the regulator.4.Turn all cooktop5.control valves to theOFF position.Turn on the gas6.supply and check alllines and connectionsfor leaks using a soapand water solution.Turn the gas shut-7.off valve to the OFFposition.Installation InstructionsOFF IconBare wireconnectionsLoop andspade terminalconnectionsL1 terminalL2 terminalL2 wireGreen wireWhite wireStrain reliefNeutral terminalLink removedGround screw4 Wire ApplianceCord ConnectionL2NeutralGroundL114-50P PlugL1 wireGaslineRegulatorconnectionAccessholesBack of range