Planning the InstallationWARNINGIMPORTANT: Observe all governing codes and ordinancesduring planning and installation. Contact your local buildingdepartment for further information.Electrical RequirementsIMPORTANT: The information below applies only to free standingunits equipped for use in the U.S.A. and units with the selfrimming option.It is the owner’s responsibility to ensure that the electricalconnection of this appliance is performed by a licensedelectrician. The electrical installation, including minimum supplywire size and grounding, must be in accordance with the NationalElectric code ANSI/NFPA 70-1993* (or latest revision) and localcodes and ordinances. A copy of this standard may be obtainedfrom:National Fire Protection Association1 Batterymarch ParkQuincy, Massachusetts 02269-9101The correct voltage, frequency and amperage must besupplied to the appliance from a separate, grounded, circuitthat is protected by a properly sized circuit breaker or timedelay fuse. Refer to the ratings on the range rating label.ER30D/ER30DSR ELECTRIC CIRCUIT REQUIREMENTSCircuit Required Total Connected Load240 Vac, 60 Hz, 30 Amps 5.6 kW (23 Amps)The ratings above are for reference only -refer to the range rating label (see page 3)Consult local building codes for the type and minimum wiregauge to use for the power requirements listed on the ratinglabel.Suggested wiring color code: Black, white, red and green.The wiring needs to be long enough to allow the rangeto be pulled out from the wall for service, while remainingconnected. See page 12 for further details.The wiring to the range must:Have a minimum rating of 250 Volts @ 30 AmpsInclude a strain reliefBe terminated by tinned leads, closed loop terminals oropen ended spade lugs with upturned endsWhere local code permits, a three (3) or four (4) wireappliance cord may be used. The appliance cord must:Be UL listed type SRD or SRDTBe equipped with a NEMA 14-50P 4 wire plug or, wherelocal code permits, a NEMA 10-50P 3 wire plug.Prior to range installation, have a licensed electrician install aconduit junction box or electrical receptacle according to thetype of wiring used.•••••◊◊◊•◊◊•NEMA 14-50P Plug NEMA 10-50P PlugElectrical Requirements -Freestanding Units for Use in CanadaIt is the owner’s responsibility to ensure that the required4 wire electrical outlet is installed by a licensed electricianas specified below prior to range installation. The electricaloutlet installation, including minimum supply wire size andgrounding, must be in accordance with all governing codesand ordinances.The correct voltage, frequency and amperage must besupplied to the appliance from a separate, grounded, circuitthat is protected by a properly sized circuit breaker or timedelay fuse. Refer to the ratings on the range rating label.ER30D-C ELECTRIC CIRCUIT REQUIREMENTSCircuit Required Total Connected Load240 Vac, 60 Hz, 30 Amps 5.6 kW (23 Amps)The ratings above are for reference only -refer to the range rating label (see page 3)Freestanding rangesequipped for use in Canadacome pre-wired with a 4 wireappliance cord and NEMA14-50P plug.Do not modify the factorywiring. The plug is designedto plug directly into a NEMA14-50R electrical receptacleinstalled by a licensedelectrician according to the above specifications.Gas Supply RequirementsCheck your local building codes for the proper method ofinstallation. In the absence of local codes, this applianceshould be installed in accordance with the National Fuel GasCode ANSI Z223.1.Be certain that the appliance being installed is correct forthe gas service provided (natural gas or LP gas). Also, ifoperating the range at an altitude above 4000 ft. (1219 m)make sure it is equipped for high altitude operation. Refer tothe range rating label and the table on page 3 to determinethe correct model.See the table below for gas supply pressure requirements.The regulator inlet accommodates a 3/4” gas line. The rangeships with a 1/2” to 3/4” adapter connected to the regulator.GAS SUPPLY PRESSURE REQUIREMENTSGas Type ManifoldPressureMinimumGas SupplyPressureMaximumGas SupplyPressureNatural Gas 5” WaterColumn6” WaterColumn 1/2 p.s.i.Propane (LP) 10” WaterColumn11” WaterColumn 1/2 p.s.i.The ratings above are for reference only -refer to the range rating label (see page 3)••••••••NEMA 14-50R Receptacle