6Refrigerator OperationWater Filter Performance DataInterior Water Filtration SystemModel AFF3 (67003523-750) Capacity 750 Gallons (2839 Liters)This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. Theconcentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permis-sible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.Substance ReductionAesthetic EffectsNSF ReductionRequirementsAverageInfluentInfluent ChallengeConcentrationMaximumEffluentAverageEffluentMinimum %ReductionAverage %ReductionChlorine Taste/OdorParticulate Class I*50% reduction85% reduction2.00 mg/L14,000,000 #/mL2.0 mg/L ± 10% At least10,000 particles/mL0.06 mg/L370,000 #/mL**0.050625 mg/L196,666 #/mL97.00%97.40%97.52%99.00%ContaminantReductionNSF ReductionRequirementsAverageInfluentInfluent ChallengeConcentrationMaximumEffluentAverageEffluentMinimum %ReductionAverage %ReductionLead: @ pH 6.5Lead: @ pH 8.50.010 mg/L0.010 mg/L0.150 mg/L†0.150 mg/L† 0.15 mg/L ± 10%0.15 mg/L ± 10%< 0.001mg/L< 0.001mg/L< 0.001mg/L< 0.001mg/L>99.30%>99.30%>99.30%>99.30%Mercury: @ pH 6.5Mercury: @ pH 8.50.002 mg/L0.002 mg/L0.006 mg/L0.006 mg/L0.006 mg/L ± 10%0.006 mg/L ± 10%0.0005 mg/L0.0018 mg/L0.0003 mg/L0.00073 mg/L91.70%69.20%95.00%88.10%Benzene 0.005 mg/L 0.0133 mg/L 0.015 mg/L ± 10% 0.0005 mg/L 0.0005 mg/L 96.10% 96.30%p-Dichlorobenzene 0.075 mg/L 0.210 mg/L 0.225 mg/L ± 10% < 0.0005 mg/L < 0.0005 mg/L >99.80% >99.80%Carbofuran 0.040 mg/L 0.0753 mg/L 0.08 mg/L ± 10% 0.027 mg/L 0.008 mg/L 64.60% 73.45%Toxaphene 0.003 mg/L 0.015 mg/L 0.15 ± 10% < 0.001mg/L < 0.001mg/L 93.3% 93.3%Atrazine 0.003 mg/L 0.0102mg/L 0.009 mg/L ± 10% < 0.0027mg/L < 0.00105mg/L 76.30% 89.40%Asbestos >99% 126.5 MF/L 107 to 108 fibers/L†† < 0.17 MF/L < 0.17 MF/L >99.99% >99.99%Live Cysts‡Turbidity>99.95%0.5 NTU122,500 #/L10.5 NTU50,000/L min.11 ± 1 NTU< 1 #/L‡0.30 NTU< 1 #/L‡0.125 NTU>99.99%97.30%>99.9998.80%Lindane 0.0002 mg/L 0.0019 mg/L 0.002 ± 10% < 0.00016mg/L 0.000035mg/L 91.80% 97.90%Tetrachloroethylene 0.005 mg/L 0.015 mg/L 0.015 mg/L ± 10% < 0.0005 mg/L < 0.0005 mg/L >96.6% >96.6%Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.9 Lpm).Pressure = 60 psig (413.7 kPa). Temp. = 68°F ± 5°F (20°C ± 3°C).* Class I particle size: >0.5 to <1 um** Test requirement is at least 100,000 particles/mL of AC Fine Test Dust† These contaminants are not necessarily in your water supply. Performance may varybased on local water conditions†† Fibers greater than 10 um in length‡ Based on the use of Cryptosporidium parvum oocystsSpecificationsWater Supply: City or wellService Flow Rate: .78 gpm (2.9 L/min) @ 60 psiWater Pressure: 35 - 120 psi (241 - 827 kPa)Water Temperature: 33° - 100°F (1° - 38°C)It is essential that operational, maintenance and filter replacementrequirements be carried out for the product to perform as adver-tised.The filter monitor system measures the amount of water thatpasses through the filter and alerts you to replace the filter.When 90% of the filter’s rated life is used, the order light comeson. When 100% of the filter’s rated life is used, the replace lightcomes on, and it is recommended that you replace the filter.For models without filter status lights, replace the filter every 6months. Use Dacor replacement cartridge AFF3.This product is for cold water use only.System tested and certified by NSF ® International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste andOdor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene,p-Dichlorobenzene, Carbofuran, Toxaphene, Cysts, Turbidity, Asbestos, Tetrachloroethylene and Lindane.Do not use with water that is microbiologically unsafe or ofunknown quality without adequate disinfection before or afterthe system. Systems certified for cyst reduction may be usedon disinfected waters that may contain filterable cysts.Refer to the Warranty and Service section for the manufacturer’slimited warranty.NSF is a registered trademark of NSF International.