8DRAIN HOSE INSTALLATION1. Drain hose connectionIn case that the drain hose is connected, bondingwork is necessary for preventing leaks, and thenmake it immovable with fixing stuff such as adhesiveband.(adhesive band is not included in product)• outside diameter of drain hose connecting hole is32mm2. Insulating treatmentInsulating treatment must be carried out for the con-denser water not to leak out from drain pipes.Be sure there is no gap between the product andhose.• Inside diameter of flexible hose connecting hole is32mm.• In case that outside temperature and humidity ishigh, make the insulating material by 10~30mm.3. Supporting and connecting pipesTo let out the condenser water, drain pipes must beat down-slope.In case that drain pipes are not at down-slope, prob-lems such as reverse flow of condenser water mightoccur.If the pipe is long, a rest that can support the pipeneeds to be installed.(to be worked within 1~1.5M)4. Horizontal extension of pipe is impossible.In case that drain hose is above the connecting hole,it must be connected up to the hole at a right anglewithin 30cm crossways from the product. Height ofthe drain hose is at a right angle within 600mm fromthe drain hose connecting hole.Warning!After connecting the flexible hose to the drain hose con-necting hole, connecting the hose up at a right angle isrestricted.outside diameter ofdrain hose connectinghole is 32mmDrain hoseconnecting holeInsulationFlexiblehosemainbodybondingworkadhesive band(not included inproduct)drainpipeMainbodypipe restpipe restdown-slope(over 1/100)elbow25A VPflexible hosedrain pipe(with down-slope)drain hoseconnectingholehorizontal extension within30cm is not impossiblewithin60cmoverhead side