7Indoor UnitWiring1) Strip wire ends (15mm).2) Match wire colours with terminal numbers on indoor and outdoorunit's terminal blocks and firmly screw wires to the correspondingterminals with the screw.3) Connect the earth wires to the corresponding terminals.Attach the earth wire so that it is not connected to the fan motor connector.4) Pull wires to make sure that they are securely latched up, then retain wireswith wire retainer.5) Shape the wires so that the service lid fits securely, then close service lid.Firmly fix the wires withthe terminal screws.Outdoor unitPower supply wire(b)Terminal blockIndoorunit Circuit breaker 11 Earth leakage(c) circuit breaker Power supply (d)Capacity Class (kW)Inter Unit wire (a)Firmly fix the wires withthe terminal screws. Earth2.5-3.7 I above 3.7 and upto 7. 14-core, 1.0 mm2 or more I 4-core, 1.5 mm2 or morePower supply wire (b) 3-core, 1.5 mm2 or moreWire Standard IS:694 or country specific s t andard.Circuit breaker size (c) 15A or more I 20Aor morePower supply (d) 50Hz 230V~or Country specificNote: Use 4-core 1.5 mm2 wire if wire is not included with the unit.� WARNING ____________________________________1_a_b1e_N_o_.6• Use a stabiliser if required by the voltage supply condition.• Do not use tapped wires, extension cords, or starburst connections, as they may cause overheating, electrical shock, or fire.• Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from theterminal block.) Doing so may cause electric shock or fire.Drain Piping1) Connect the drain hose, as described right. The drain hose shouldbe inclined downward.No trap is permitted.2) Remove the air filters and pour some water into the drain pan to check the waterflows smoothly.Do not put the endof the hose in water.3) When drain hose requires extension, obtain an extension hose commercially available.�Be sure to thermally insulate the indoor section of the extension hose.4) When connecting a rigid polyvinyl chloride pipe (nominal diameter13mm) directly to the drain hose attached to the indoor unit as withembedded piping work, use any commercially available drainsocket (nominal diameter 13mm) as a joint.Heat insulation tube(field supply)-i: - a:==) - rr=jDrain hose supplied Commercially Commerciallywith the indoor unit available drain available rigidsocket (nominal polyvinyl chloridediameter 13mm) pipe (nominaldiameter 13mm)