Main Functions Si04-306E46 Function and Control1.2 Power-Airflow Dual Flaps, Wide Angle Louvers andAuto-SwingPower-airflowDual FlapsThe large flaps send a large volume of air downwards to the floor. The flap provides an optimumcontrol area in cooling, heating and dry mode.Heating ModeDuring heating mode, the large flap enables direct warm air straight downwards. The flappresses the warm air above the floor to reach the entire room.Cooling ModeDuring cooling mode, the flap retracts into the indoor unit. Then, cool air can be blown far andpervaded all over the room.Wide-AngleLouvresThe louvres, made of elastic synthetic resin, provide a wide range of airflow that guarantees acomfortable air distribution.Auto-Swing The following table explains the auto-swing process for heating, cooling, dry and fan :Outline of 3-DAirflowAlternative repetition of vertical and horizontal swing motions enables uniform air-conditioning ofthe entire room. This function is effective for starting the air conditioner.Detail of theActionWhen the horizontal swing and vertical swing are both set to auto mode, the airflow become 3-Dairflow and the horizontal swing and vertical swing motions are alternated. The order of swingmotion is such that it turns counterclockwise, starting from the right upper point as viewed to thefront side of the indoor unit.Vertical Swing (up and down) Horizontal Swing(right and left)Heating Cooling Dry Fan Heating, Cooling15˚55˚15˚55˚(R2813)10˚40˚ 10˚40˚(R2814)5˚35˚ 5˚35˚(R2815)5˚55˚5˚55˚(R2816)50˚50˚(R2817) (R1024)