Main Functions SiBE12-712C78 Function and Control1.9 ECONO ModeOutline FTK(X)S20-50D, ATKS20-35E, ATXS20-50E, FVXS25-50FEcono Mode is a function that sets a limit for power consumption. A maximum powerconsumption of 1000 W (40 class) or 1300W (50 class) is the limit for the 2MK(X)S40/50F. Thismode is useful for preventing circuit breakers from being overloaded by the use of multiple airconditioners and other electrical devices. The function is easily activated from the remotecontroller by pushing the ECONO button. Econo Mode is available for all wall-mounted models.Details ECONO mode can be activated while the unit is running. The remote controller can send theECONO command when the unit is in COOL, HEAT, DRY, or AUTO operation. When the ECONO command is valid, the input current is under reducing control.Also, the upper limit of frequency is restricted.From start up until settemperature is reached40 class : 1000W50 class : 1300W This diagram is a representation for illustrative purposes only. Maximum capacity decreases during Econo Mode, requiringmore time to reach the set temperature.Maximum duringnormal operationPower consumptionTimeNormaloperationEconoModeMaximum duringEcono Mode(R8461)