5 EnglishNAMES AND FUNCTIONS OF PARTSRefer to figure abovea Indoor unitb Outdoor unitcRemote controllerFor using of BRC1E or wireless remote con-troller, please refer to operation manual pro-vided with the remote controller.The remote controller may not be neededdepending on the system configuration.d Suction aire Discharged airf Air outletg Airflow flap (Vertical airflow direction adjust-ment flap)h Airflow flap (Horizontal airflow directionadjustment flap)i Refrigerant piping, electric wire connection,earth wirej Drain pipek Air inletThe built-in air filter removes dust and dirt.lEarth wireWire to ground from the outdoor unit to pre-vent electrical shocks and fire.eeabcddffghijkl3. OPERATION RANGEIf the temperature or the humidity is beyond the fol-lowing conditions, safety devices may work and theair conditioner may not operate, or sometimes,water may drop from the indoor unit.COOLING [°C]HEATING [°C]D B: Dry bulb temperatureWB: Wet bulb temperatureThe setting temperature range of the remote con-troller is 16°C to 32°C depends on heating/coolingmode.OUTDOORUNITINDOOR OutdoortemperatureTemperature HumidityRZQG DB 18~37 ≤80% DB –15~50WB 12~28RZQSG71~140 DB 20~37 ≤80% DB –15~43WB 14~28RZQ200 DB 20~37 ≤80% DB –5~46WB 14~28OUTDOORUNITINDOOR OutdoortemperatureTemperature HumidityRZAG71~140 DB 18~37 ≤80% DB –20~52WB 12~28RZASG71~140 DB 20~37 ≤80% DB –15~46WB 14~28OUTDOOR UNIT IndoortemperatureOutdoortemperatureRZQG DB 10~27 DB –19.5~21WB –20~15.5RZQSG71 DB 10~27 DB –14~21WB –15~15.5RZQSG100~140 DB 10~27 DB –14~21WB –15~15.5RZQ200 DB 10~27 DB –14~21WB –15~15OUTDOOR UNIT IndoortemperatureOutdoortemperatureRZAG71~140 DB 10~27 DB –19.5~21WB –20~15.5RZASG71~140 DB 10~27 DB –14~21WB –15~15.5