5 English[ CAUTION ]Only use the included parts or parts which match the specifications when installing the unit.• Install the indoor unit no less than 2.5 m above the floor. Where unavoidably lower, take whatmeasures are necessary to keep hands out of the air outlet.2. Use the installation panel for installation.Consider whether the location where the unit will be mounted can support its weight, and if necessary,strengthen by adding supporting boards or beams before mounting. Make sure that any reinforcementis strong enough to withstand vibration and loud noise. (The mounting pitch is listed on the mountingpattern paper, so refer to it when considering whether strengthening is necessary or not.)3. The indoor unit may not be directly installed on the wall.Use the attached installation panel before installing the unit.4. INDOOR UNIT INSTALLATION1. Detach the installation panel from the indoor unit.• The installation panel is attached to the rear of the unit.To detach, remove the screws from the bottom of the panel. ( Refer to Fig. 1 )2. Attach the installation panel to the wall, using the paper pattern for installation.(a)Check the position of the drill hole for the piping through-hole using the included pattern paper.• Keep approximately 50 mm between the ceiling and the unit.(b)Temporarily tack the mounting board, and use a level to make sure that it is either level or slightlytipped down on the side of the drainage pipe.(c)Secure the mounting board to the wall with either a screw or a bolt.• If using the attached wood screws, fix 4 screws to each the left and right sides (total of 8 or more).• If using bolts, attach 2 M8 bolts to each the left and right sides (total of 4).• If installing the unit on a concrete wall, attach the panel with a field supplied anchor (M8).≥ 50 ≥ 50≥ 50≥ 2502500 or higherfrom the floorFor installationin high placesRequired space for installation or servicingFloorAir outletAir inletObstruction1) InstallationpanelScrewsFig. 1