3 OperationOperation manual3FBA35~140A2VEBSplit system air conditioners4P456964-1 – 2017.04c User interfaced Air inlete Air outletf Refrigerant piping and electric wiringg Drain pipeh Earth wire to ground outdoor unit to prevent electricshocks.CAUTIONDo not insert fingers, rods or other objects into the air inletor outlet. Do not remove the fan guard. When the fan isrotating at high speed, it will cause injury.CAUTIONNever touch the internal parts of the controller.Do not remove the front panel. Some parts inside aredangerous to touch and appliance problems may happen.For checking and adjusting the internal parts, contact yourdealer.NOTICEDo not wipe the controller operation panel with benzine,thinner, chemical dust cloth, etc. The panel may getdiscoloured or the coating peeled off. If it is heavily dirty,soak a cloth in water-diluted neutral detergent, squeeze itwell and wipe the panel clean. Wipe it with another drycloth.NOTICENever press the button of the user interface with a hard,pointed object. The user interface may be damaged.NOTICENever pull or twist the electric wire of the user interface. Itmay cause the unit to malfunction.2.2 Information requirements for fancoil unitsItem Symbol Value UnitCooling capacity (sensible) Prated,c A kWCooling capacity (latent) Prated,c B kWHeating capacity Prated,h C kWTotal electric power input Pelec D kWSound power level (per speedsetting, if applicable)LWA E dBContact details:DAIKIN INDUSTRIES CZECH REPUBLIC s.r.o. U Nové Hospody1/1155, 301 00 Plzeň Skvrňany, Czech RepublicA B C D EFBA125A 9.06 4.94 13.50 0.23 62FBA140A 9.98 5.42 15.50 0.23 623 Operation3.1 Operation rangeUse the system in the following temperature and humidity ranges forsafe and effective operation.For combination with R410A outdoor unit, refer to the following table:Outdoor units Cooling HeatingRR71~125 Outdoortemperature–15~46°C DB —Indoortemperature18~37°C DB12~28°C WB—RQ71~125 Outdoortemperature–5~46°C DB –9~21°C DB–10~15°C WBIndoortemperature18~37°C DB12~28°C WB10~27°C DBRXS35~60 Outdoortemperature–10~46°C DB –15~24°C DB–16~18°C WBIndoortemperature18~32°C DB 10~30°C DB3MXS40~684MXS68~805MXS90Outdoortemperature–10~46°C DB –15~24°C DB–16~18°C WBIndoortemperature18~32°C DB 10~30°C DBRZQG71~140 Outdoortemperature–15~50°C DB –19~21°C DB–20~15.5°C WBIndoortemperature18~37°C DB12~28°C WB10~27°C DBRZQSG71~140 Outdoortemperature–15~46°C DB –14~21°C DB–15~15.5°C WBIndoortemperature20~37°C DB14~28°C WB10~27°C DBRZQ200~250 Outdoortemperature–5~46°C DB –14~21°C DB–15~15°C WBIndoortemperature20~37°C DB14~28°C WB10~27°C DBIndoor humidity ≤80%(a)For combination with R32 outdoor unit, refer to the following table:Outdoor units Cooling HeatingRXM35~60 Outdoortemperature–10~46°C DB –15~24°C DB–16~18°C WBIndoortemperature18~32°C DB 10~30°C DB3MXM40~684MXM68~805MXM90Outdoortemperature–10~46°C DB –15~24°C DB–16~18°C WBIndoortemperature18~32°C DB 10~30°C DBRZAG71~140 Outdoortemperature–20~52°C DB –19.5~21°C DB–20~15.5°C WBIndoortemperature18~37°C DB12~28°C WB10~27°C DBRZASG71~140 Outdoortemperature–15~46°C DB –14~21°C DB–15~15.5°C WBIndoortemperature20~37°C DB14~28°C WB10~27°C DBAZAS71~140 Outdoortemperature–15~46°C DB –14~21°C DB–15~15.5°C WBIndoortemperature20~37°C DB14~28°C WB10~27°C DBIndoor humidity ≤80%(a)