1 General safety precautionsInstaller and user reference guide5FCAG35~140AVEBSplit system air conditioners4P473927-1 – 2017.03WARNINGMake sure installation, testing and applied materialscomply with applicable legislation (on top of theinstructions described in the Daikin documentation).CAUTIONWear adequate personal protective equipment (protectivegloves, safety glasses,…) when installing, maintaining orservicing the system.WARNINGTear apart and throw away plastic packaging bags so thatnobody, especially children, can play with them. Possiblerisk: suffocation.DANGER: RISK OF BURNING▪ Do NOT touch the refrigerant piping, water piping orinternal parts during and immediately after operation. Itcould be too hot or too cold. Give it time to return tonormal temperature. If you must touch it, wearprotective gloves.▪ Do NOT touch any accidental leaking refrigerant.WARNINGProvide adequate measures to prevent that the unit can beused as a shelter by small animals. Small animals thatmake contact with electrical parts can cause malfunctions,smoke or fire.CAUTIONDo NOT touch the air inlet or aluminium fins of the unit.NOTICE▪ Do NOT place any objects or equipment on top of theunit.▪ Do NOT sit, climb or stand on the unit.NOTICEWorks executed on the outdoor unit are best done underdry weather conditions to avoid water ingress.In accordance with the applicable legislation, it might be necessaryto provide a logbook with the product containing at least: informationon maintenance, repair work, results of tests, stand-by periods,…Also, at least, following information must be provided at anaccessible place at the product:▪ Instructions for shutting down the system in case of an emergency▪ Name and address of fire department, police and hospital▪ Name, address and day and night telephone numbers forobtaining serviceIn Europe, EN378 provides the necessary guidance for this logbook.1.3.2 Installation site▪ Provide sufficient space around the unit for servicing and aircirculation.▪ Make sure the installation site withstands the unit's weight andvibration.▪ Make sure the area is well ventilated. Do NOT block anyventilation openings.▪ Make sure the unit is level.Do NOT install the unit in the following places:▪ In potentially explosive atmospheres.▪ In places where there is machinery that emits electromagneticwaves. Electromagnetic waves may disturb the control system,and cause malfunction of the equipment.▪ In places where there is a risk of fire due to the leakage offlammable gases (example: thinner or gasoline), carbon fibre,ignitable dust.▪ In places where corrosive gas (example: sulphurous acid gas) isproduced. Corrosion of copper pipes or soldered parts may causethe refrigerant to leak.Instructions for equipment using R32 refrigerantIf applicable.WARNING▪ Do NOT pierce or burn.▪ Do NOT use means to accelerate the defrostingprocess or to clean the equipment, other than thoserecommended by the manufacturer.▪ Be aware that R32 refrigerant does NOT contain anodour.WARNINGThe appliance shall be stored so as to prevent mechanicaldamage and in a well-ventilated room without continuouslyoperating ignition sources (example: open flames, anoperating gas appliance or an operating electric heater)and have a room size as specified below.NOTICE▪ Do NOT reuse joints which have been used already.▪ Joints made in installation between parts of refrigerantsystem shall be accessible for maintenance purposes.WARNINGMake sure installation, servicing, maintenance and repaircomply with instructions from Daikin and with applicablelegislation (for example national gas regulation) and areexecuted only by authorised persons.Installation space requirementsNOTICE▪ Pipework shall be protected from physical damage.▪ Installation of pipework shall be kept to a minimum.WARNINGIf appliances contain R32 refrigerant, then the floor area ofthe room in which the appliances are installed, operatedand stored must be larger than the minimum floor areadefined in table below A (m2). This applies to:▪ indoor units,▪ outdoor units installed or stored indoors (example:winter garden, garage, machinery room),▪ pipework in unventilated spaces.To determine the minimum floor area1 Determine the total refrigerant charge in the system (= factoryrefrigerant charge + additional refrigerant amountcharged).