1-10! WARNING ! CAUTIONInstallation and maintenance should be performed by qualifiedpersons who are familiar with local code and regulation, andexperienced with this type of appliance.All field wiring must be installed in accordance with the nationalwiring regulation.Ensure that the rated voltage of the unit corresponds to that ofthe name plate before commencing wiring work according to thewiring diagram.The unit must be GROUNDED to prevent possible hazard dueto insulation failure.All electrical wiring must not touch the refrigerant piping, or anymoving parts of the fan motors.Confirm that the unit has been switched OFF before installingor servicing the unit.Disconnect from the main power supply before servicing the airconditioner unit.DO NOT pull out the power cord when the power is ON. This maycause serious electrical shocks which may result in fire hazards.Keep the indoor and outdoor units, power cable and transmissionwiring, at least 1m from TVs and radios, to prevent distorted picturesand static. {Depending on the type and source of the electricalwaves, static may be heard even when more than 1m away}.•••••••••Please take note of the following important points wheninstalling.Do not install the unit where leakage of flammable gas mayoccur.If gas leaks and accumulates around the unit, it may causefire ignition.Ensure that the drainage piping is connected properly.If the drainage piping is not connected properly, it maycause water leakage which will dampen the furniture.Do not overcharge the unit.This unit is factory pre-charged. Overcharge will causeover-current or damage to the compressor.Ensure that the unit’s panel is closed after service orinstallation.Unsecured panels will cause the unit to operate noisily.Sharp edges and coil surfaces are potential locations whichmay cause injury hazards. Avoid from being in contact withthese places.Before turning off the power supply, set the remote controller’sON/OFF switch to the “OFF” position to prevent the nuisancetripping of the unit. If this is not done, the unit’s fans will startturning automatically when power resumes, posing a hazard toservice personnel or the user.Do not install the units at or near doorway.Do not operate any heating apparatus too close to the air conditionerunit or use in room where mineral oil, oil vapour or oil steam exist,this may cause plastic part to melt or deform as a result of excessiveheat or chemical reaction.When the unit is used in kitchen, keep flour away from going intosuction of the unit.This unit is not suitable for factory used where cutting oil mist oriron powder exist or voltage fluctuates greatly.Do not install the units at area like hot spring or oil refinery plantwhere sulphide gas exists.Ensure the color of wires of the outdoor unit and the terminalmarkings are same to the indoors respectively.IMPORTANT : DO NOT INSTALL OR USE THE AIRCONDITIONER UNIT IN A LAUNDRY ROOM.Don’t use joined and twisted wires for incoming power supply.The equipment is not intended for use in a potentially explosiveatmosphere.•••••••••••••••Important information regarding the refrigerant usedThis product contains fluorinated greenhouse gases covered by theKyoto Protocol.Do not vent gases into the atmosphere.Refrigerant type: R407CGWP (1) value: 1652.5(1) GWP = global warming potentialPlease fill in with indelible ink,1 the factory refrigerant charge of the product,2 the additional refrigerant amount charged in the field and1 + 2 the total refrigerant chargeon the refrigerant charge label supplied with the product.The filled out label must be adhered in the proximity of the productcharging port (e.g. onto the inside of the service cover).1 factory refrigerant charge of the product:see unit name plate (2)2 additional refrigerant amount charged inthe field3 total refrigerant charge4 Contains fluorinated greenhouse gasescovered by the Kyoto Protocol5 outdoor unit6 refrigerant cylinder and manifold forcharging(2) In case of multiple indoor systems, only 1 label must be adhered*,mentioning the total factory refrigerant charge of all indoor unitsconnected in the refrigerant system.Periodical inspections for refrigerant leaks may be required dependingon European or local legislation. Please contact your local dealer formore information.* on the outdoor unit■■■INSTALLATION MANUALSAFETY PRECAUTIONSThis manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit.Special adjustment may be necessary to suit local requirements.Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by laypersons.This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack ofexperience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsiblefor their safety.Children should be supervised to ensure that they do not play with the appliance.