1EnglishSAFETY PRECAUTIONS! CAUTIONPlease take note of the following important points wheninstalling.• Do not install the unit where leakage of flammable gasmay occur.If gas leaks and accumulates around the unit, it maycause fire ignition.• Ensure that the drainage piping is connected properly.If the drainage piping is not connected properly, it maycause water leakage which will dampen the furniture.• Do not overcharge the unit.This unit is factory pre-charged, Overcharge will causeover-current or damage to the compressor.• Ensure that the unit’s panel is closed after service orinstallation.Unsecured panels will cause the unit to operate noisily.• Sharp edges and coil surfaces are potential locations whichmay cause injury hazards. Avoid from being in contactwith these places.• Before turning off the power supply set the remotecontroller’s ON/OFF switch to the “OFF” position toprevent the nuisance tripping of the unit. If this is not done,the unit’s fans will start turning automatically when powerresumes, posing a hazard to service personnel or the user.• Do not operate any heating apparatus too close to the airconditioner unit. This may cause the plastic panel to melt ordeform as a result of the excessive heat.• Ensure the color of wires of the outdoor unit and theterminal markings are same to the indoors respectively.• IMPORTANT : DO NOT INSTALL OR USE THE AIRCONDITIONER UNIT IN A LAUNDRY ROOM.! WARNING• Installation and maintenance should be performed byqualified persons who are familiar with local code andregulation, and experienced with this type of appliance.• All field wiring must be installed in accordance with thenational wiring regulation.• Ensure that the rated voltage of the unit corresponds tothat of the name plate before commencing wiring workaccording to the wiring diagram.• The unit must be GROUNDED to prevent possible hazarddue to insulation failure.• All electrical wiring must not touch the refrigerant pipingor any moving parts of the fan motors.• Confirm that the unit has been switched OFF beforeinstalling or servicing the unit.• Disconnect from the main power supply before servicingthe air conditioner unit.• DO NOT pull out the power cord when the power is ON.This may cause serious electrical shocks which may resultin the fire hazards.• Keep the indoor and outdoor units, power cable andtransmission wiring, at least 1m from TVs and radios, toprevent distorted pictures and static. {Depending on thetype and source of the electrical waves, static may be heardeven when more than 1m away}.This manual provides the procedures of installation to ensure a safe and good standard of operation for the airconditioner unit.Special adjustment may be necessary to suit local requirements.Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.INSTALLATION MANUALDisposal requirementsDismanteling of the unit, treatment of the refrigerant, oil and other parts shall be done in accordance with local and nationalregulation.