Installation manual7 FFQ25~60C2VEBSplit System air conditioners4P341094-1B – 2013.04Wiring example and how to set the remotecontrollerHow to connect wiring (See figure 9) Inter unit wiringRemove the control box lid (1) and connect the inter unit wiringterminal block inside with the matching numbers and connectthe ground wire to the grounding terminal. While doing this, pullthe wires inside through the hole in the control box lid and clampthe wires as indicated in the figure. Remote controller wiringRemove the control box lid (1) and pull the wires inside throughthe hole in the control box lid and connect to the remotecontroller wiring terminal block. Securely fix the wiring using aclamp as indicated in the figure. After connectionAttach the small sealing (supplied with the unit) around thecables to prevent infiltrating of water from the outside into theunit. If two or more cables are used, divide the small sealing intothe required number of pieces and wrap them around all thecables. Attach the control box lidPrecautions1 Observe the notes mentioned below when wiring to the powersupply terminal board.- Use a round crimp-style terminal for insulation sleeve forconnection to the terminal block for wiring the units. Whennone are available, follow the instructions below.- Do not connect wires of different gauge to the same powersupply terminal. (Looseness in the connection may causeoverheating.)- When clamping wiring, use the clamps (delivered with theunit) to prevent outside pressure being exerted on the wiringconnections. Tie up firmly. When doing the wiring, make surethe wiring is neat and does not cause the control box to stickup. Close the cover firmly.- When connecting wires of the same gauge, connect themaccording to the figure.Use the specified electric wire. Connect the wire securely tothe terminal. Lock the wire down without applying excessiveforce to the terminal. Use torques according to the tablebelow.- When attaching the control box lid, make sure not to pinchany wires.- After all wiring connections are done, fill in any gaps in thecasing wiring holes with putty or insulation material (fieldsupply) thus to prevent small animals or dirt from entering theunit from outside and causing short circuits in the control box.2 Keep total current of crossover wiring between indoor units lessthan 12 A. Branch the line outside the terminal block of the unitin accordance with electrical equipment standards, when usingtwo power wiring of a gauge greater than 2 mm 2 (Ø1.6).The branch must be sheathed in order to provide an equal orgreater degree of insulation as power supply wiring itself.3 Do not connect wires of different gauge to the same groundingterminal. Looseness in the connection may deteriorate theprotection.4 Remote controller wiring should be located at least 50 mm awayfrom inter unit wiring and other wiring. Not following thisguideline may result in malfunction due to electrical noise.5 For the remote controller wiring, refer to the "Installation manualof the remote controller" supplied with the remote controller.6 Never connect the inter unit wiring to the remote controller wiring.This mistake could damage the entire system.7 Use only specified wires and tightly connect wires to theterminals. Be careful that wires do not place external stress onthe terminals. Keep wiring in neat order so that they do notobstruct other equipment such as popping open the servicecover. Make sure the cover closes tight. Incomplete connectionscould result in overheating, and in the worst case, electric shockor fire.1 Control box lid2 Inter unit wiring3 Earth cable4 Terminal block for power supply5 Clamp (field supply)6 Remote controller wiring7 Remote controller wiring terminal block8 Opening for cables9 Wiring diagram label (on the back side of the control box lid)Tightening torque (N•m)Terminal block for remote controller 0.79~0.97Terminal block for wiring the units 1.18~1.441 2 3 1 Round crimp-style terminal2 Attach insulation sleeve3 WiringNOTE The customer has the ability to select the remotecontroller thermistor.