5 EnglishRefer to figure 1 on page [1]• Operating procedure varies with heat pump typeand cooling only type. Contact your Daikin dealerto confirm your system type.• To protect the unit, turn on the main power switch6 hours before operation.• If the main power supply is turned off during oper-ation, operation will restart automatically after thepower turns back on again.Operate in the following order.OPERATION MODE SELEC-TORPress OPERATION MODE SELECTOR but-ton several times and select the OPERATIONMODE of your choice as follows. COOLING OPERATION ......................... “ ” HEATING OPERATION .......................... “ ” AUTOMATIC OPERATION ..................... “ ”• In this operation mode, COOL/HEATchangeover is automatically conducted. FAN OPERATION................................... “ ” DRY OPERATION .................................. “ ”• The function of this program is to decrease thehumidity in your room with the minimum tem-perature decrease.• Micro computer automatically determinesTEMPERATURE and FAN SPEED.• This system does not go into operation if theroom temperature is below 16°C.20FAN SPEED CONTROL BUTTONPress this button to select the fan speed,HIGH or LOW, of your choice.21OPERATION MODE SELECTOR BUTTONPress this button to select OPERATIONMODE.22 AIR FLOW DIRECTION ADJUST BUTTONRefer to “AIR FLOW DIRECTION ADJUST ”.NOTE• For the sake of explanation, all indications areshown on the display in Figure 1 contrary toactual running situations.6. OPERATION PROCEDURECOOLING, HEATING, AUTOMATIC, FAN,AND PROGRAM DRY OPERATION1Refer to figure 3 on page [1]• For cooling only type, “COOLING” , “FAN” and“DRY” operation are able to select.ON/OFFPress ON/OFF BUTTONOPERATION lamp lights up or goes off and the sys-tem starts or stops OPERATION.[EXPLANATION OF HEATING OPERATION]DEFROST OPERATION• As the frost on the coil of an outdoor unit increase,heating effect decreases and the system goesinto DEFROST OPERATION.• The indoor unit fan stops and the remote control-ler display shows “ ”.• After 6 to 8 minutes (maximum 10 minutes) ofDEFROST OPERATION, the system returns toHEATING OPERATION.Regarding outside air temperature and heat-ing capacity• The heating capacity of the air conditionerdeclines as the outside air temperature falls. Insuch a case, use the air conditioner in combina-tion with other heating systems.• A warm air circulating system is employed, andtherefore it takes some time until the entire roomis warmed up after the start of operation.• An indoor fan runs to discharge a gentle windautomatically until the temperature inside the airconditioner reaches a certain level. At this time,the remote controller displays “ ”. Leave itas it stands and wait for a while.• When the warm air stays under the ceiling andyour feet are cold, we recommend that you use acirculator (a fan to circulate the air inside theroom). For details, consult your dealer.202_EN_3PN05140-1.fm Page 5 Thursday, November 14, 2002 3:37 PM