3 Dimensional drawingsModel AFH35GZ 12.70FHY35GZFH45GZ 15.90FHY45GZ1 Air discharge grille2 Air suction grille3 Air filter4 Gas pipe connection φA Flare connection5 Liquid pipe connection J6.35 Flare connection6 Drain pipe connection V.P.207 Grounding terminal M48 Suspension bracket9 Rear piping connection hole - slit hole10 Upper refrigerant piping connection hole - slit hole11 Right side piping connection hole - slit hole12 Rear left side drain piping connection hole - slit hole13 Left side drain piping connection hole - slit hole14 Right side drain piping connection hole - slit hole15 Power supply / control wiring connection (upper)16 Power supply / control wiring connection (rear)17 Remote control code connection (upper)18 Remote control code connection (rear)19 Rear piping connection hole - slit hole J100Notes:1. Name plate: sticked on the bottom part of fan housing in suction grille2. When using a remote controller, this position will be a signal receiver. Refer to the detaileddrawing of the remote controller3. The standard length of remote control cord is approximately 3m.(0.5mm x 2 cores x J5.4 0.D.)(Suspensionposition)500 mm ormore(Installation space) (Installation space)Suspension boltService space60 mm or moreunit (mm)FHY35∼45GZ7V1Slit hole position for rear piping connection(from the front)Drain outlet V.P.20(for left piping)DAIKIN name plate(See note 2)60 mm or moreService space(Installation space)Wall hole position for rearpiping connection(from the front)3TW20524-1A(Suspension position)FH35BZV1FHYP35∼45BV1View from the front780 From the floor side 2500 or more(Required space)Note:1. Location of unit’s name plate: bottom of fan housing inside thesuction grille.2. In case of using infrared remote control, this position will be a signalreceiver. Refer to the drawing of infrared remote control in detail.3. The remote control code is the standard (about 3m outside themachine) attached.(0.5 mm 2 x 2 Wicks x O.D. J5.4)(It is not attached in VRV.)1 Air discharge grille2 Air suction grille3 Air filter4 Gas pipe connection J12.7 flare5 Liquid pipe connection J6.4 flare6 Drain pipe connection VP207 Earth terminal (inside the electric components box) M48 Suspension bracket9 Backward piping and wiring connection opening lid10 Upward piping and wiring connection opening lid11 Right side pipe connection - slit hole12 Left back drain pipe connection - slit hole13 Right side drain pipe connection - slit hole14 Right side drain piping connection hole- slit hole15 Hole of wall for taking out in piping back J10016 Upward drain pipe connection J6017 Upward gas pipe connection J3618 Upward liquid pipe connection J26Position: hole of wall for taking out in piping backFor height installationFloor side300or moreBrand name plate(For left piping)30 or more 30 or more(Service space)(View from the front)(Hanging position)Hanging boltPosition slit hole for taking out in piping back3D027536ADrain pipe connectionVP20Obstacle(Service space)(View from the front)(Hanging position)(Required space)(Required space)(Note 2)• Ceiling Suspended Unit • R-407C • FH(Y)-GZ/BZ/FHYP-B1039• Split - Sky Air • Indoor Units