Si01-406 R50/60CV1ARemoval Procedure 1794.3 Removal of CompressorProcedure Warning Be sure to wait 10 minutes or more after turning off all power suppliesbefore disassembling work.Step Procedure Points Make sure that there is norefrigerant in the unitbefore disassembling.WARNINGIf refrigerant gas leaks duringservicing work, ventilate thearea. (If refrigerant gascontacts flames, hazardousgas can generate.) When removing sound-insulation material, do notpull it with excessive force,since it is inserted betweenpipes.1 Pull out soundinsulation material (sideinsulation) from rightside.2 Disconnect suction pipeand discharge pipe ofcompressor at brazedsections.