SiUS041501E FunctionsList of Functions 21. FunctionsCategory FunctionsFTKN09/12NMVJURKN09/12NMVJUFTXN09/12NMVJURXN09/12NMVJUCategory FunctionsFTKN09/12NMVJURKN09/12NMVJUFTXN09/12NMVJURXN09/12NMVJUBasicFunction Inverter (with inverter power control) z z Health &Clean Air-purifying filter — —Operation limit for cooling (°CDB) 10 ~46 10 ~46 Photocatalytic deodorizing filter — —Air-purifying filter with photocatalyticdeodorizing function — —Operation limit for cooling (°FDB) 50 ~114.8 50 ~114.8 Titanium apatite photocatalyticair-purifying filter (option) z zOperation limit for heating (°CWB) — –15 ~18 Air filter (prefilter) z zOperation limit for heating (°FWB) — 5 ~64.4Wipe-clean flat panel z zWashable grille — —PAM control z z MOLD PROOF operation — —Standby electricity saving z z Good-sleep cooling operation — —Compressor Oval scroll compressor — — Timer WEEKLY TIMER — —Swing compressor z z Count up-down ON/OFF timer z zRotary compressor — — 24-hour ON/OFF TIMER — —Reluctance DC motor z z NIGHT SET mode z zComfortableAirflowPower-airflow flap (horizontal blade) z z Worry Free(Reliability &Durability)Auto-restart (after power failure) z zPower-airflow dual flaps — — Self-diagnosis (R/C, LED) z zPower-airflow diffuser — — Wiring error check function — —Wide-angle louvers (vertical blade) z z Anti-corrosion treatment of outdoor heatexchanger z zAuto-swing (up and down) z zAuto-swing (right and left) — — Flexibility Multi-split / split type compatible indoorunit — —3-D airflow — —COMFORT AIRFLOW operation z z H/P, C/O compatible indoor unit — —ComfortControlAuto fan speed z z Flexible power supply correspondence — —Indoor unit quiet operation z z Chargeless 32.8 ft(10 m)32.8 ft(10 m)NIGHT QUIET mode (automatic) — —OUTDOOR UNIT QUIET operation(manual) — — Either side drain (right or left) z zPower selection — —INTELLIGENT EYE operation — — Low temperature cooling operation(–15°C) (5°F) — —Quick warming function — zHot-start function — z °F/°C changeover R/C temperaturedisplay (factory setting: °F) z zAutomatic defrosting — zOperation Automatic operation — z RemoteControl 5-rooms centralized controller (option) z zProgram dry function z z Remote control adaptor(normal open-pulse contact) (option) z zFan only z zLifestyleConvenience New POWERFUL operation(non-inverter) — — Remote control adaptor(normal open contact) (option) z zInverter POWERFUL operation z z DIII-NET compatible (adaptor) (option) z zPriority-room setting — — RemoteController Wireless z zCOOL / HEAT mode lock — — Wired (option) z zHOME LEAVE operation — —ECONO operation z zIndoor unit ON/OFF button z zSignal receiving sign z zR/C with back light — —Temperature display — —Note: z : Available— : Not available