Field Settings for FTX, FVXS Series SiUS091601EA207 Part 7 Trial Operation and Field SettingsCaution4.2 When 2 Units are Installed in 1 RoomOutline When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding wirelessremote controller can be set for different address.FTX09/12/15NMVJU1. Remove the battery cover of the remote controller.2. Cut the address jumper.3. Press the center of TEMP button and OFF switch on the remote controller at the same time.4. Select A (address setting) with TEMP or TEMP button.5. Press FAN button to enter the address setting mode.The indoor unit operation lamp blinks for 1 minute.6. Press indoor unit ON/OFF switch while the operation lamp is blinking.7. Press FAN button on the remote controller for 5 seconds to return to the normal mode.Replace the remote controller if you cut a jumper unintentionally.Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.Wireless Remote ControllerR7000282R7000281Indoor UnitR7000283AddressEXISTJumperCUT12JumperON/OFFOPERATION lampIndoor unitON/OFF switch