3ŶEnglishAccessoriesA Mounting plate 1 B Mounting plate fixing screw3/16” × 1” (M4 × 25mm) 7 C Titanium apatite photocatalyticair-purifying filter *1*2 2D Wireless remote controller 1 E Remote controller holder 1 F Fixing screw for remote controllerholder 1/8” × 13/16” (M3 × 20mm) 2G Dry battery AAA. LR03(alkaline) 2 H Indoor unit fixing screw3/16” × 1/2” (M4 × 12mm) 2 J Insulation tape 1K Operation manual 1 L Installation manual 1* 1 Only for FTX(K)09/12/18/24** 2 09/12 class: without frame18/24 class: with frameChoosing an Installation SiteBefore choosing the installation site, obtain user approval.1� Indoor unitThe indoor unit should be positioned in a place where:1) the restrictions on the installation requirements specified in “Indoor unit installation drawings” on page 4 are met,2) both the air inlet and air outlet are unobstructed,3) the unit is not exposed to direct sunlight,4) the unit is away from sources of heat or steam,5) there is no source of machine oil vapour (this may shorten the indoor unit service life),6) cool/warm air is circulated throughout the room,7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may affect the remotecontroller range,8) the unit is at least 3.3ft (1m) away from any television or radio set (the unit may cause interference with the picture orsound),9) no laundry equipment is nearby.2� Wireless remote controllerTurn on all the fluorescent lamps in the room, if any, and find a location where the remote controller signals are properlyreceived by the indoor unit (within 23ft (7m)).