5 Outdoor Unit Indoor Unit1. Air filter2. Photocatalytic deodorizing filter orAir purifying filter:• These filters are attached to the inside of the airfilters.3. Air inlet4. Front grille5. Grille tab6. Room temperature sensor:• It senses the air temperature around the unit.7. INTELLIGENT EYE sensor:• It detects the movements of people and auto-matically switches between normal operationand energy saving operation. (page 18.)8. Display9. Air outlet10. Flaps (horizontal blades): (page 12.)11. Louvres (vertical blades):• The louvres are inside of the air outlet.(page 13.)12. Indoor Unit ON/OFF switch: (page 10.)• Push this switch once to start operation.Push once again to stop it.• The operation mode refers to the followingtable.• This switch is useful when the remote controlleris missing.13. Operation lamp (green)14. TIMER lamp (Yellow): (page 20.)15. HOME LEAVE lamp (red): (page 16.)16. Signal receiver:• It receives signals from the remote controller.• When the unit receives a signal, you will hear ashort beep.• Operation start .............beep-beep• Settings changed ..........beep• Operation stop ..............beeeeep Outdoor Unit17. Air inlet: (Back and side)18. Air outlet19. Refrigerant piping and inter-unit cable20. Drain hose21. Earth terminal:• It is inside of this cover.22. Outside air temperature sensor:• It senses the ambient temperature around theunit.Appearance of the outdoor unit may differ from some models.192220211817Mode TemperaturesettingAir flowrateFTKE COOL 22°C AUTOFTXE AUTO 25°C AUTO