Forced Cooling Operation SiBE041012_A219 Trial Operation and Field Settings2. Forced Cooling OperationIndoor UnitOutdoor Unit (25/35 class)Item Forced CoolingConditions The forced cooling operation is allowed when both the following conditions aremet.1) The outdoor unit is not abnormal and not in the 3-minute standby mode.2) The outdoor unit is not operating.Start The forced cooling operation starts when any of the following conditions isfulfilled.1) Press the forced cooling operation ON/OFF button (S1W) on the indoor unitfor 5 seconds.2) Press the forced cooling operation ON/OFF switch (SW1) on the outdoorunit.Commandfrequency 25/35 class: 58 Hz50 class: 66 HzEnd The forced cooling operation ends when any of the following conditions isfulfilled.1) The operation ends automatically after 15 minutes.2) Press the forced cooling operation ON/OFF button (S1W) on the indoor unitagain.3) Press the ON/OFF button on the remote controller.4) Press the forced cooling operation ON/OFF switch (SW1) on the outdoorunit.Others The protection functions are prior to all others in the forced cooling operation.ON/OFF button (S1W)(R13329)1 2 3Push hereScrewdriver(R13824)