The indoor unit must be installed in such a way so as to preventshort circuit of the cool discharged air with the hot return air.Please follow the installation clearance shown in the figure. Donot place the indoor unit where there could be direct sunlightshining on it. Also, this location must be suitable for pipingand drainage, and be away from doors or windows.min. 50(Space formaintenance)Air flow(Indoor)The refrigerant piping can be routed to the unit in a numberof ways (left or right from the back of the unit), by using thecut-out holes on the casing of the unit. Bend the pipes carefullyto the required position in order to align it with the holes. Forthe side and bottom out, hold the bottom of the piping andthen position it to the required direction. The condensationdrain hose can be taped to the pipes.Right-side, right-back or right-bottom pipingmin. 50(Space formaintenance)min. 30(Space forperformance)Required spaceRight-back pipingAll dimensions are in mm Right-bottompipingRight-side pipingRemove pipe port coverhere for right-side pipingLeft-back pipingLeft-side pipingLeft-bottom pipingLeft-side, left-back or left-bottom pipingINSTALLATION OF THE INDOOR UNITRemove pipe port coverhere for right-bottom pipingBind coolant pipeand drain hosetogether withinsulating tape.Remove pipe portcover here forleft-side pipingRemove pipe port coverhere for left-bottom piping1-8