3 About the unitInstallation manual4(A)(F)TXP20~35M5V1BDaikin room air conditioner3P519299-4B – 2018.123 About the unitWARNING: FLAMMABLE MATERIALThe refrigerant inside this unit is mildly flammable.3.1 System layoutafcedba Indoor unitb Service lidc Air filterd Titanium apatite deodorizing and silver particle filter (onlyfor FTXP)e Refrigerant piping, drain hose and interconnection cablef Insulation tape3.2 Operation rangeOperation mode Operation rangeCooling(a)(b) ▪ Outdoor temperature: –10~46°C▪ Indoor temperature: 18~32°C▪ Indoor humidity: ≤80%Heating(a) ▪ Outdoor temperature: –15~24°C▪ Indoor temperature: 10~30°CDrying(a) ▪ Outdoor temperature: –10~46°C▪ Indoor temperature: 18~32°C▪ Indoor humidity: ≤80%If operated outside the operation range:(a) A safety device might stop the operation of the system.(b) Condensation might occur on the indoor unit and drip.4 Preparation4.1 Preparing the installation siteWARNINGThe appliance shall be stored in a room withoutcontinuously operating ignition sources (example: openflames, an operating gas appliance or an operating electricheater).4.1.1 Installation site requirements of theindoor unitINFORMATIONThe sound pressure level is less than 70 dBA.▪ Air flow. Make sure nothing blocks the air flow.▪ Drainage. Make sure condensation water can be evacuatedproperly.▪ Wall insulation. When conditions in the wall exceed 30°C and arelative humidity of 80%, or when fresh air is inducted into thewall, then additional insulation is required (minimum 10 mmthickness, polyethylene foam).▪ Wall strength. Check whether the wall or the floor is strongenough to support the weight of the unit. If there is a risk, reinforcethe wall or the floor before installing the unit.▪ Spacing. Install the unit at least 1.8 m from the floor and keep thefollowing requirements in mind for distances from the walls andthe ceiling:≥50 ≥50≥30(mm)4.2 Preparing refrigerant piping4.2.1 Refrigerant piping requirementsRefrigerant piping diameterUse the same diameters as the connections on the outdoor units:Class L1 liquid piping L1 gas piping20~35 Ø6.4 Ø9.5Refrigerant piping material▪ Piping material: Phosphoric acid deoxidised seamless copper.▪ Flare connections: Only use annealed material.▪ Piping temper grade and thickness:Outer diameter(Ø)Temper grade Thickness (t)(a)6.4 mm (1/4") Annealed (O) ≥0.8 mmtØ(a) Depending on the applicable legislation and the unit'smaximum working pressure (see "PS High" on the unitname plate), larger piping thickness might be required.4.2.2 Refrigerant piping insulationPipe outer diameter(Øp)Insulation innerdiameter (Øi)Insulation thickness(t)6.4 mm (1/4") 8~10 mm ≥10 mmØiØitØpØpIf the temperature is higher than 30°C and the humidity is higherthan RH 80%, the thickness of the insulation materials should be atleast 20 mm to prevent condensation on the surface of theinsulation.