Operation Manual EDUS04112964 Split Type Air Conditioners FTXS-L Series19ECONO OperationECONO operation is a function which enables effi cient operation by limiting themaximum power consumption value.This function is useful for cases in which attention should be paid to ensure a circuitbreaker will not trip when the product runs alongside other appliances.To start ECONO operationPress during operation.“• ” is displayed on the LCD.To cancel ECONO operationPress again.“• ” is no longer displayed on the LCD.Running current andpower consumptionFrom start up until settemperature is reachedTimeMaximum duringnormal operationMaximum duringECONO modeNormaloperationECONOmodeThis diagram is a representation for illustrative purposes only.•The maximum running current and power consumption of the air conditioner in ECONOoperation vary with the connecting outdoor unit.NOTENotes on ECONO operationECONO operation can only be set when the unit is running. Pressing the operation stop button causes the settings to be canceled, and the•“ ” is no longer displayed on the LCD.ECONO operation is a function which enables effi cient operation by limiting the power consumption of the outdoor unit (operating frequency).•ECONO operation functions in AUTO, COOL, DRY, and HEAT operation.•POWERFUL and ECONO operation cannot be used at the same time.•Priority is given to the function of whichever button is pressed last.If the level of power consumption is already low, ECONO operation will not drop the power consumption.•