5 EnglishIndoor Unit InstallationIntelligent-eye sensorCaution1) Do not hit or violently push the Intelligent-eye sensor. This can lead to damage and malfunction.2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor’s detection area.AM4 × 25LM4 × 16LM3 × 20LD Wirelessremote controllerERemotecontroller holderBefore screwing the remotecontroller holder to the wall,make sure that controlsignals are properlyreceived by indoor unit.Service lidOpening service lidService lid is opening/closing type.Opening method1) Remove the service lid screws.2) Pull out the service lid diagonallydown in the direction of the arrow.3) Pull down.Intelligent-eye sensorWrap the insulation pipe withthe finishing tape from bottomto top.Cut thermal insulationpipe to an appropriatelength and wrap it withtape, making sure that nogap is left in the insulationpipe’s cut line.Caulkpipe holegapwith putty.MountingplateClipMark (rear side)Bottom frameFront grilleHow to attach the indoor unit.Hook the claws of the bottom frameto the mounting plate.If the claws are difficult to hook,remove the front grille.How to remove the indoor unit.Push up the marked area (at thelower part of the front grille) torelease the claws. If it is difficult torelease, remove the front grille.The mounting plateshould be installed on awall which can support theweight of the indoor unit.30 mm or more from ceilingFront panel50 mm or more from walls(on both sides)Air filtersB Titanium Apatite PhotocatalyticAir-Purifying Filter (2)A Mounting plateAir filterTitanium ApatitePhotocatalyticAir-Purifying FilterFilter frameTab