SiBE041011EC Main FunctionsFunction and Control 261.8 NIGHT SET ModeOutline When the OFF TIMER is set, NIGHT SET Mode is automatically activated. NIGHT SET Modekeeps the airflow rate setting.Detail NIGHT SET Mode continues operation at the target temperature for the first one hour, thenautomatically raises the target temperature slightly in cooling, or lowers it slightly in heating.This prevents excessive cooling in summer and excessive heating in winter to ensurecomfortable sleeping conditions, and also conserves electricity.1.9 ECONO OperationOutline ECONO operation reduces the maximum operating current and the power consumption.This operation is particularly convenient for energy-saving. It is also a major bonus whenbreaker capacity does not allow the use of multiple electrical devices and air conditioners.It can be easily activated by pushing the ECONO button on the wireless remote controller.Detail When this function is activated, the maximum capacity also decreases. The remote controller can send the ECONO command when the unit is in cooling, heating,dry, or automatic operation. This function can only be set when the unit is running. Pressingthe ON/OFF button on the remote controller cancels the function. This function and POWERFUL operation cannot be used at the same time. The latestcommand has the priority.(R22018)TIMER operationNIGHT SET Mode ONTarget temperature+0.5˚Ctemperature shiftOperation stopsat the set hours0.5˚C1 hourTIMER operationNIGHT SET Mode ONTarget temperature–2˚Ctemperature shift1 hour2˚C(R22029)ECONO Operation(R19427)Normal operationMaximum during normal operationMaximum during ECONO operationTimePowerconsumptionand current