Main Functions SiMT041311E31 Function and Control1.9 Sensor OperationOperation∗ Refer to the operation manual for details.1.9.1 3-Area INTELLIGENT EYE OperationOutline The 2 INTELLIGENT EYE sensors detect the presence of the user by dividing the room (sensorrange) into 3 areas, to decide whether to blow air directly at or to avoid a person.The 2 INTELLIGENT EYE sensors judge whether there is a person according to the signalsfrom the 2 sensors for 3 areas (left, centre, right).Detail Comfort or FocusComfort or Focus can be selected in remote controller.Comfort: Adjusts the airflow direction to avoid directly blowing at a person.Focus: Adjusts the airflow direction to directly blow at a person.Flap movement(1) When Comfort is set and the INTELLIGENT EYE sensor detects a person• Horizontal flap: It blows air downward in heating operation, upward in cooling operation.• Vertical flap: It adjusts the airflow to avoid directly blowing at a person.(2) When Focus is set and the INTELLIGENT EYE sensor detects a person• Horizontal flap: It adjusts the airflow direction so that the maximum airflow rate is achieved.• Vertical flap: It blows air to directly blow at a person.(R19704)3-Area INTELLIGENTEYE / AUTO OFFIndoor unitCentreRightLeftTop view(R19764)Sensor 1(left)Sensor 2(right)