Instruction SiBE06-70864 System Configuration13 Air flow selection• Make air flow selection according to what suits you.When setting the air flow selection switch to .• Air conditioner automatically decides the appropriate blowing pattern depending on the operatingmode/situation.• During Dry mode, so that cold air does not come into direct contact with people, air is blownupper air outlet.When setting the air outlet selection switch to .• Regardless of the operating mode or situation, air blows from the upper air outlet.• Use this switch when you do not want air coming out of the lower air outlet. (While sleeping etc.)CAUTIONOperating mode Situation Blowing patternCOOL mode• When the room has become fullycool, or when one hour haspassed since turning on the airconditioner.• So that air does not come intodirect contact with people, air isblown upper air outlet, room tem-perature is equalized.• At start of operation or othertimes when the room is not fullycooled.• Air is blown from the upper andlower air outlets for high speedcooling during COOL mode, andfor filling the room with warm airduring HEAT mode.HEAT mode• At times other than below.(Normal time.)• At start or when air temperatureis low.• So that air does not come intodirect contact with people. Air isblown upper air outlet.• Do not try to adjust the flap by hand.• When adjusting by hand, the mechanism may not operate properly or condensation may dripfrom air outlets.