Daikin FXAQ15AUV1B Operation Manual
Also see for FXAQ15AUV1B: Installation manual
English 21. SAFETY PRECAUTIONSTo gain full advantage of the air conditioner’s functions and toavoid malfunction due to mishandling, please read this oper-ation manual carefully before use.This product comes under the term “appliances not accessi-ble to the general public”.• This appliance is intended to be used by expert ortrained users in shops, in light industry and on farms,or for commercial and household use by lay persons.• This appliance can be used by children aged from 8years and above and persons with reduced physical,sensory or mental capabilities or lack of experienceand knowledge if they have been given supervision orinstruction concerning use of the appliance in a safeway and understand the hazards involved.• Children shall not play with the appliance.• Cleaning and user maintenance shall not be made bychildren without supervision.• This manual classifies the precautions into WARNINGSand CAUTIONS. Be sure to follow all the precautionsbelow: They are all important for ensuring safety.WARNING ....... Indicates a potentially hazardous situa-tion which, if not avoided, could result indeath or serious injury.CAUTION ........ Indicates a potentially hazardous situa-tion which, if not avoided, may result inminor or moderate injury.It may also be used to alert againstunsafe practices.• After reading, keep this manual in a convenient placeso that you can refer to it whenever necessary. If theequipment is transferred to a new user, be sure also tohand over the manual.WARNINGWhen the air conditioner is malfunctioning (givingoff a burning odor, etc.), turn off the power to the airconditioner and contact your local dealer.Continued operation under such circumstances mayresult in a failure, electric shocks or a fire.Consult your local dealer regarding modification,repair and maintenance of the air conditioner.Improper workmanship may result in water leakage,electric shocks or a fire.Be sure to use fuses with the correct ampere read-ing.Do not use improper fuses, copper or other wiring as asubstitute, as this may result in electric shocks, a fire,injury or damage to the air conditioner.Consult your local dealer if the air conditioner sub-merges owing to a natural disaster, such as a floodor typhoon.Do not operate the air conditioner in that case, or other-wise a malfunction, electric shocks, or a fire may result.Start or stop the air conditioner with the remote con-troller. Never use the power circuit breaker for thispurpose.Otherwise, it may cause a fire or water leakage. Further-more, if an automatic restart control is provided againstpower failure and the power is recovered, the fan willrotate suddenly and may cause injury.Do not use the air conditioner in the atmospherecontaminated with oil vapor, such as cooking oil ormachine oil vapor.Oil vapor may cause crack damage to the air conditioner,electric shocks, or a fire.Do not use flammable materials (e.g., hairspray orinsecticide) near the air conditioner.Do not clean the air conditioner with organic sol-vents such as paint thinner.The use of organic solvents may cause crack damage tothe air conditioner, electric shocks, or a fire.Do not use the air conditioner in places with exces-sive oily smoke, such as cooking rooms, or in placeswith flammable gas, corrosive gas, or metal dust.Using the air conditioner in such places may cause a fireor air conditioner failures.Beware of a fire in case of refrigerant leakage.If the air conditioner is not operating correctly, i.e. notgenerating cool or warm air, refrigerant leakage could bethe cause. Consult your local dealer for assistance. Therefrigerant used for the air conditioner is safe and nor-mally does not leak. However, if the refrigerant leaks andgets in contact with a naked burner, heater or cooker, itmay generate hazardous compounds. Turn off the airconditioner and call your local dealer. Turn on the air con-ditioner after the qualified service person makes sure toconfirm that the leakage is repaired.Do not place objects, including rods, your fingers,etc., in the air inlet or outlet.Injury may result due to contact with the air conditioner’shighspeed fan blades.Consult your local dealer regarding cleaning theinside of the air conditioner.Improper cleaning may cause breakage of plastic parts,water leakage and other damage as well as electricshocks.Be aware that prolonged, direct exposure to cool orwarm air from the air conditioner, or to air that is toocool or too warm can be harmful to your physicalcondition and health.Consult your local dealer about installation work.Information requirements for fan coil unitsItem Symbol Value UnitCooling capacity(sensible) P rated, c A kWCooling capacity (latent) P rated, c B kWHeating capacity Prated, h C kWTotal electric power input P elec D kWSound power level(per speed settingif applicable)LWA E dBContact details DAIKIN INDUSTRIES CZECH REPUBLIC s.r.o.U Nové Hospody 1/1155, 301 00 PlzeňSkvrňany, Czech RepublicTHE ABOVE TABLE RELATES TO THE MODELSAND VALUES STATED IN THIS TABLEModels A B C D EFXAQ15 1.5 0.2 1.9 0.025 51FXAQ20 1.9 0.3 2.5 0.029 52FXAQ25 2.2 0.6 3.2 0.034 53FXAQ32 2.7 0.9 4.0 0.035 55FXAQ40 3.5 1.0 5.0 0.026 55FXAQ50 4.2 1.4 6.3 0.039 58FXAQ63 5.3 1.8 8.0 0.065 63 |
Related manuals for Daikin FXAQ15AUV1B
Daikin FXAQ15PAV1 Operation Manual
Daikin FXAQ12MVJU Operation Manual
Daikin F Operation Manual
Daikin FAQ100BUV1B Operation Manual
Daikin FAQ100BUV1B Operation Manual
Daikin FAQ100BUV1B Operation Manual
Daikin FXAQ15AUV1B Installation Manual
Daikin FXAQ20PV1 Operation Manual
Daikin FXAQ20AVM Operation Manual
Daikin FXAQ07MVJU Operation Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine