• Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB• VRV ® Systems • Indoor Units41 SpecificationsMotor Speed (cooling) High rpm 975 1,161 1,060 1,218Low rpm 840 960 813 920Speed (heating) High rpm 975 1,161 1,060 1,218Low rpm 840 960 813 920Fan Motor Output (high) W 350Drive Direct driveRefrigerant Name R-410ASound level Cooling Sound power(nominal)dBA 59 63 61 66Cooling Sound Pressure High dBA 37 38 38 40Low dBA 30 32 32 33Heating Sound Pressure High dBA 37 38 38 40Low dBA 30 32 32 33Piping connections Liquid (OD) Type Flare connectionDiameter mm 9.52Gas Type Flare connectionDiameter mm 15.9Drain Diameter mm VP25 (O.D. 32 / I.D. 25)Heat Insulation Both liquid and gas pipesDecoration Panel Model BYBS71DJW1 BYBS125DJW1 BYBS125DJW1 BYBS125DJW1Colour White (10Y9/0,5)Dimensions Height mm 55Width mm 1,100 1,500 1,500 1,500Depth mm 500Weight kg 4.5 6.5 6.5 6.5Drain-up Height mm 625Air Filter Resin net with mold resistanceRefrigerant control Electronic expansion valveSafety devices PC board fusePC board fuse (fan driver)Drain pump fuseNotes Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping : 7.5m, level difference : 0m.Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB,6°CWB, equivalent refrigerant piping : 7.5m, level difference : 0m.Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.The sound pressure values are mentioned for a unit installed with rear suction1-1 TECHNICAL SPECIFICATIONS FXSQ63P7VEB FXSQ80P7VEB FXSQ100P7VEB FXSQ125P7VEB